Warranty 

 

IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise 

expressly specified.  Damage to instruments caused by incorrect power or misapplication, is not covered by 

warranty.  

If there are any questions regarding power, intended application, or general usage, please consult with 

your local sales contact or distributor.

  Batteries and other expendable hardware items are not covered by 

warranty. 

 
Service 

 

Because of the sophisticated nature of IMI instrumentation, field repair is typically 

NOT

 recommended and may 

void any warranty.  If factory service is required, return the instrumentation according to the “Return Procedure” 

stated below.  

A repair and/or replacement quotation will be provided prior to servicing at no charge.

  Before 

returning the unit, please consult a factory IMI applications engineer concerning the situation as certain problems 

can often be corrected with simple on-site procedures. 

 
Return Procedure 

 

To expedite returned instrumentation, contact a factory IMI applications engineer for a RETURN MATERIAL 

AUTHORIZATION (RMA) NUMBER.

  Please have information available such as model and serial number.  Also, 

to insure efficient service, 

provide a written description of the symptoms and problems with the equipment to a 

local sales representative or distributor, or contact IMI if none are located in your area.

 

 

Customers outside the U.S. should consult their local IMI distributor for information on returning equipment.  For 

exceptions, please contact the International Sales department at IMI to request shipping instructions and an RMA.  

For assistance, please call (716) 684-0003, or fax us at (716) 684-3823.  You may also receive assistance via e-

mail at 

[email protected]

 or visit our web site at 

www.pcb.com

 

Summary of Contents for IMI SENSORS 691C41T

Page 1: ...x Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail im...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ry Switch Boxes Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI SENSORS AND INSTRUMENT...

Page 7: ...RING Table of Contents Introduction Page 3 Installation Page 4 Grounding the Enclosure Page 4 Input Wiring Page 5 Output Wiring Page 6 Using the Enclosure Page 6 Calibrating the Enclosure Page 6 ESD W...

Page 8: ...t provide simultaneous vibration and temperature signals Specifications and drawings are below for reference Model Number 691C41 691C42 Channel Count 6 12 Input Connector 4 socket screw terminal strip...

Page 9: ...el and stainless steel boxes include two factory installed mounting brackets on the top and bottom of the box Hardware for fastening the mounting brackets to the installation surface are to be provide...

Page 10: ...l shielding system ground planes on PC Board mounting panel and switch enclosure an external earth ground wire must be connected To do this the bottom right inner mounting hole has a double nut includ...

Page 11: ...iate connector mate in the box and modulate the switch to the appropriate channel If the output terminals are not being used then the data collector must provide power for the sensor in order to for a...

Page 12: ...voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on...

Page 13: ...ion will be provided prior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected wi...

Page 14: ...o have your purchase price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days...

Page 15: ...ERSIONS Optional versions have identical specifications and accessories as listed for the standard model except where noted below More than one option may be used 691004 6 Individual PGME07 Cord Grips...

Page 16: ...13 OUTLINE DRAWING 65589 1 OF 1 375X MODEL 691C41T 6 CHANNEL SWITCH BOX DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 KSR 2 19 18 JDM 2 19 18 RMB 2 19 18 65589 PCB Piezotronics Inc claims proprietary...