7.0

 

Gain Switch  

 
Table  2  illustrates  the  proper  Gain  switch  settings  on  switch  block  SW2  (shown  in  Figure  4)  based  on  the  input 
signal from the sensor with which it is used.  Set each of the four switches to either 1 (ON) or 0 (OFF) according to 
the sensor’s excitation voltage and sensitivity. 
 

 

Table 2 – Switch Positions for Input Signal Range Adjustment 

Sensitivity (mV/V) 

Vexc = 5 VDC 

Sensitivity (mV/V) 

Vexc = 10 VDC 

SW2 Settings 

1    2    3    4 

SW2 

1 = SW “ON” 

7.0 to 11.0 

3.5 to 5.5 

0    0    0    1 

4.6 to 7.0 

2.3 to 3.5 

0    0    1    0 

3.0 to 4.6 

1.5 to 2.3 

0    1    0    0 

2.0 to 3.0 

1.0 to 1.5 

1    0    0    0 

1.5 to 2.0 

0.75 to 1.0 

1    0    1    0 

1.0 to 1.5 

0.50 to 0.75 

1    1    0    1 

0.9 to 1.0 

0.45 to 0.50 

1    1    1    1 

 

 

 

8.0

 

Mounting 

 

To mount the Series 8162 signal conditioner, reference the hole patterns in Figure 2 for specific dimensions.   Figure 
3 illustrates the exterior dimensions of the conditioner.  Dimensions are expressed in inches (millimeters).  

 

 

Figure 2 

 

 

Figure 3 

3.110 (79) 

1.968 (50) 

 0.19 (4.8) 

1.968 (50) 

Summary of Contents for 8162-011A

Page 1: ...ignal Condition Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...er Cabling 2 4 0 Analog Outputs 2 5 0 Transducer Excitation 2 6 0 Calibration 3 7 0 Gain Switches 4 8 0 Mounting 4 Figures 1 Series 8162 Signal Conditioner 2 2 Mounting Hole Dimensions 4 3 Exterior Di...

Page 7: ...terminal J1 Reference Figure 4 for the J1 terminal location Tighten the screw to fasten the wire in place d Next insert the Ground wire into the screw 2 position on terminal J1 Tighten the screw to f...

Page 8: ...alue of mechanical input The calibration can then be transferred to the installed calibration resistor for convenience in checking later b Replace the installed calibration resistor with one supplied...

Page 9: ...t Sensitivity mV V Vexc 5 VDC Sensitivity mV V Vexc 10 VDC SW2 Settings 1 2 3 4 SW2 1 SW ON 7 0 to 11 0 3 5 to 5 5 0 0 0 1 4 6 to 7 0 2 3 to 3 5 0 0 1 0 3 0 to 4 6 1 5 to 2 3 0 1 0 0 2 0 to 3 0 1 0 to...

Page 10: ...nside View J1 Input Power J3 Output Connections P2 Voltage Output P1 Bridge Excitation SW1 RCAL Switch SW2 Gain Switch 1 RCAL R5 4mA adjust 20mA adjust R22 Fine Span R23 Coarse Zero J2 Transducer Conn...

Page 11: ...56 6 mm x 94 0 mm x 64 8 mm Electrical Connector input output screw terminal screw terminal All specifications are at room temperature unless otherwise specified In the interest of constant product i...

Page 12: ...NE DRAWING 27193 1 OF 1 FULL MODEL 8162 SIGNAL CONDITIONER SAC 05 24 13 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 27193 PCB Load Torque Inc claims proprietary rights in the information disclosed h...

Reviews: