background image

 

Model Number

 

8162-011A

 

STRAIN GAGE SENSOR SIGNAL CONDITION

 

Revision: B 

ECN #: 41446

 

 

Performance 

ENGLISH 

SI 

Electrical Filter Cutoff Frequency

 

100 Hz

 

100 Hz

 

[2]

 

Frequency Range

 

0 to 1000 Hz

 

0 to 1000 Hz

 

 

Input Signal(sensor sensitivity)

 

0.5 to 11 mV/V

 

0.5 to 11 mV/V

 

[3]

 

Environmental 

Enclosure Rating

 

NEMA 4X

 

IP66.

 

 

Excitation Current

 

60 mA

 

60 mA

 

 

Temperature Range

 

+32 to +158 °F

 

0 to +70 °C

 

 

Electrical 

Offset Voltage(@min. gain)

 

± 50% of F.S.

 

± 50% of F.S.

 

 

Offset Voltage

(@max.gain)

 

± 70% of F.S.

 

± 70% of F.S.

 

 

Excitation Voltage

 

10 VDC

 

10 VDC

 

[1]

 

Output Voltage

 

± 10 VDC

 

± 10 VDC

 

[1]

 

Output Current

 

4 to 20 mA

 

4 to 20 mA

 

 

Power Required

 

12 to 28 Vdc

 

12 to 28 Vdc

 

 

Physical 

Size (Length x Height x Width)

 

2.23 in x 3.70 in x 2.55 in

 

56.6 mm x 94.0 mm x 64.8 mm

 

 

Electrical Connector(input/output)

 

screw terminal

 

screw terminal

 

 

All specifications are at room temperature unless otherwise specified. 
In the interest of constant product improvement, we reserve the right to change specifications without notice. 

ICP

®

 is a registered trademark of PCB Group, Inc. 

 

OPTIONAL VERSIONS 

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

 

 
 
 
 

 

 

NOTES:

[1] Factory Adjustable
[2] Filtered via 2-pole active filter.
[3] User Adjustable.

 

Entered: AP

 

Engineer: JSD

 

Sales: KWW

 

Approved: DA

 

Spec Number:

 

Date: 6/13/2013

 

Date: 6/13/2013

 

Date: 6/13/2013

 

Date: 6/13/2013

 

23725 

 

PCB Load & Torque, Inc. 
24350 Indoplex Circle 
Farmington Hills, MI 48335 
UNITED STATES 
Phone: 866-684-7107 
Fax: 716-684-0987 
E-Mail: [email protected] 
Web site: http://www.pcbloadtorque.com 

Summary of Contents for 8162-011A

Page 1: ...ignal Condition Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...er Cabling 2 4 0 Analog Outputs 2 5 0 Transducer Excitation 2 6 0 Calibration 3 7 0 Gain Switches 4 8 0 Mounting 4 Figures 1 Series 8162 Signal Conditioner 2 2 Mounting Hole Dimensions 4 3 Exterior Di...

Page 7: ...terminal J1 Reference Figure 4 for the J1 terminal location Tighten the screw to fasten the wire in place d Next insert the Ground wire into the screw 2 position on terminal J1 Tighten the screw to f...

Page 8: ...alue of mechanical input The calibration can then be transferred to the installed calibration resistor for convenience in checking later b Replace the installed calibration resistor with one supplied...

Page 9: ...t Sensitivity mV V Vexc 5 VDC Sensitivity mV V Vexc 10 VDC SW2 Settings 1 2 3 4 SW2 1 SW ON 7 0 to 11 0 3 5 to 5 5 0 0 0 1 4 6 to 7 0 2 3 to 3 5 0 0 1 0 3 0 to 4 6 1 5 to 2 3 0 1 0 0 2 0 to 3 0 1 0 to...

Page 10: ...nside View J1 Input Power J3 Output Connections P2 Voltage Output P1 Bridge Excitation SW1 RCAL Switch SW2 Gain Switch 1 RCAL R5 4mA adjust 20mA adjust R22 Fine Span R23 Coarse Zero J2 Transducer Conn...

Page 11: ...56 6 mm x 94 0 mm x 64 8 mm Electrical Connector input output screw terminal screw terminal All specifications are at room temperature unless otherwise specified In the interest of constant product i...

Page 12: ...NE DRAWING 27193 1 OF 1 FULL MODEL 8162 SIGNAL CONDITIONER SAC 05 24 13 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 27193 PCB Load Torque Inc claims proprietary rights in the information disclosed h...

Reviews: