background image

returning 

any 

equipment 

to 

PCB 

Piezotronics, 

contact 

your 

local 

distributor,  sales  representative,  or 
factory  customer  service  representative 
to  obtain  a  Return 

Warranty,  Service, 

Repair,  and  Return  Policies  and 
Instructions 

Materials  Authorization 

(RMA)  Number.  This  RMA  number 
should be clearly marked on the outside 
of  all  package(s)  and  on  the  packing 
list(s)  accompanying  the  shipment.  A 
detailed  account  of  the  nature  of  the 
problem(s)  being  experienced  with  the 
equipment  should  also  be  included 
inside  the  package(s)  containing  any 
returned materials.   
 
A  Purchase  Order,  included  with  the 
returned  materials,  will  expedite  the 
turn-around  of  serviced  equipment.  It  is 
recommended  to  include  authorization 
on  the  Purchase  Order  for  PCB  to 
proceed  with  any  repairs,  as  long  as 
they  do  not  exceed  50%  of  the 
replacement  cost  of  the  returned 
item(s).  PCB  will  provide  a  price 
quotation 

or 

replacement 

recommendation  for  any  item  whose 
repair  costs  would  exceed  50%  of 
replacement cost, or any item that is not 
economically  feasible  to  repair.  For 
routine 

calibration 

services, 

the 

Purchase 

Order 

should 

include 

authorization  to  proceed  and  return  at 
current  pricing,  which  can  be  obtained 
from 

factory 

customer 

service 

representative.   
 

Warranty 

–  All  equipment  and  repair 

services  provided  by  PCB  Piezotronics, 
Inc.  are  covered  by  a  limited  warranty 
against 

defective 

material 

and 

workmanship  for  a  period  of  one  year 
from  date  of  original  purchase.  Contact 

PCB  for  a  complete  statement  of  our 
warranty.  Expendable  items,  such  as 
batteries  and  mounting  hardware,  are 
not  covered  by  warranty.  Mechanical 
damage  to  equipment  due  to  improper 
use  is  not  covered  by  warranty. 
Electronic circuitry failure caused by the 
introduction  of  unregulated  or  improper 
excitation 

power 

or 

electrostatic 

discharge is not covered by warranty. 
 

Contact  Information 

–  International 

customers  should  direct  all  inquiries  to 
their  local  distributor  or  sales  office.  A 
complete  list  of  distributors  and  offices 
can 

be 

found 

at 

www.pcb.com. 

Customers within the United States may 
contact  their  local  sales  representative 
or 

factory 

customer 

service 

representative.  A  complete  list  of  sales 
representatives 

can 

be 

found 

at 

www.pcb.com. 

Toll-free 

telephone 

numbers  for  a  factory  customer  service 
representative, 

in 

the 

division 

responsible  for  this  product,  can  be 
found on the title page at the front of this 
manual.  Our  ship  to  address  and 
general contact numbers are:   
 
PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840  
24-hour SensorLine

SM

: (716) 684-0001  

Website: www.pcb.com 

E-mail: [email protected]  
 
 
 
 
 
 
 
 

 

Summary of Contents for 8162-011A

Page 1: ...ignal Condition Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...er Cabling 2 4 0 Analog Outputs 2 5 0 Transducer Excitation 2 6 0 Calibration 3 7 0 Gain Switches 4 8 0 Mounting 4 Figures 1 Series 8162 Signal Conditioner 2 2 Mounting Hole Dimensions 4 3 Exterior Di...

Page 7: ...terminal J1 Reference Figure 4 for the J1 terminal location Tighten the screw to fasten the wire in place d Next insert the Ground wire into the screw 2 position on terminal J1 Tighten the screw to f...

Page 8: ...alue of mechanical input The calibration can then be transferred to the installed calibration resistor for convenience in checking later b Replace the installed calibration resistor with one supplied...

Page 9: ...t Sensitivity mV V Vexc 5 VDC Sensitivity mV V Vexc 10 VDC SW2 Settings 1 2 3 4 SW2 1 SW ON 7 0 to 11 0 3 5 to 5 5 0 0 0 1 4 6 to 7 0 2 3 to 3 5 0 0 1 0 3 0 to 4 6 1 5 to 2 3 0 1 0 0 2 0 to 3 0 1 0 to...

Page 10: ...nside View J1 Input Power J3 Output Connections P2 Voltage Output P1 Bridge Excitation SW1 RCAL Switch SW2 Gain Switch 1 RCAL R5 4mA adjust 20mA adjust R22 Fine Span R23 Coarse Zero J2 Transducer Conn...

Page 11: ...56 6 mm x 94 0 mm x 64 8 mm Electrical Connector input output screw terminal screw terminal All specifications are at room temperature unless otherwise specified In the interest of constant product i...

Page 12: ...NE DRAWING 27193 1 OF 1 FULL MODEL 8162 SIGNAL CONDITIONER SAC 05 24 13 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 27193 PCB Load Torque Inc claims proprietary rights in the information disclosed h...