Manual 21354 Rev E 
ECN 50523 

 

 

 

Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

[email protected]

 

Repair inquiries

[email protected]

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for 482C15/NP

Page 1: ...Signal Conditioner Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...82C05 482C15 GENERAL OPERATION MANUAL For powering ICP sensors and in line charge converters this signal conditioner provides a cost effective method for powering small numbers of sensor channels The...

Page 7: ...2 Safety Considerations 1 1 3 Equipment Rating 2 1 4 Model 482C15 System Description 2 1 5 Model 482C05 System Description 4 1 6 Installation 4 1 7 Grounding Techniques 4 1 8 Unit Power 5 1 9 Maintena...

Page 8: ...heading used in this manual explains dangers that might result in personal injury or death Always read the associated information very carefully before performing the indicated procedure The CAUTION...

Page 9: ...ICP source current 0 to 20 mA Jumper selectable Voltage input mode Jumper selectable gain of x1 x10 x100 482C15 Only Lighted power indicator on the front panel Rear panel BNC input output connectors...

Page 10: ...he PC board Each channel can be set to your selected gain and other options The selection of all these features with jumpers allows the 482C15 to have the functionality of many other higher priced uni...

Page 11: ...that of most sensors and is close to an open circuit voltage of 26VDC The photo on the cover is shown with the unit on and no sensors attached so the OPEN LED is on The SHORT light indicates a very lo...

Page 12: ...plied with unit Plug the adapter into any 100 240VAC 47 63Hz power source attach the supplied ferrite clamp on the AC cord to ensure CE conformance and press the ON OFF button 1 7 2 Power Optional Aut...

Page 13: ...ctral Noise 10 Hz 0 60 V Hz 0 60 V Hz 4 Spectral Noise 100 Hz 0 22 V Hz 0 22 V Hz 4 Spectral Noise 1 kHz 0 22 V Hz 0 22 V Hz 4 Spectral Noise 10 kHz 0 19 V Hz 0 19 V Hz 4 Broadband Electrical Noise 1...

Page 14: ...003 005 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 25495 1 OF 1 5X MODEL 482C SERIES 4 CHANNEL SIGNAL CONDITIONER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 SMB 12 16 11 ECB 12 16 11 KEN L 12 16...

Reviews: