MULTICHANNEL SIGNAL CONDITIONER MODEL 482C GENERAL OPERATION MANUAL

 

5

 

 
2. Insure that the sensor does not pick up line noise from the body under test.  The case of the sensor should be isolated 
from the body under (ground) using an isolation pad.  The isolation pad breaks the loop formed by the signal path of the 
sensor to the unit and the return (ground) from the unit back to the sensor. 
 
3. Make sure that all equipment signal grounds of the test system are tied to the Earth ground at a single point and the 
connections linking the equipment ground are made using a wire that can provide a very low impedance connection. 

 

1-7.

 

Unit Power 

1-7.1.

 

Power: Standard AC Line adapter Model 488A04 (supplied with unit) 

 
Plug  the  adapter  into  any  100-240VAC    47-63Hz  power  source,  attach  the  supplied  ferrite  clamp  on  the  AC  cord  to 
ensure CE conformance, and press the “ON/OFF” button.   
 

1-7.2.

 

Power: Optional Auto adapter Model 488A11 

 
Plug the adapter into a 12VDC  power source, or Automobile cigar lighter socket and press the “ON/OFF” button.  

 

 
1-7.3.

 

Power: Using other 36VDC Power Sources, or batteries. (Not supplied with unit) 

 
When using any 36VDC power source to power the unit, make sure to observe the correct pin out, as indicated on the 
rear panel of the unit. Standard 5-pin din connector.  
 

CAUTION 3: Refer to the rear panel for proper input voltage. Only PCB supplied power sources will 
ensure noise specifications and CE ratings. 

 

1-8.

 

Maintenance and Repair 

 

It is not recommended that the customer attempt repairs of the Model 482C15 or 482C05.  Should trouble occur, contact 
the factory for assistance.  

Summary of Contents for 482C15/NP

Page 1: ...Signal Conditioner Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...82C05 482C15 GENERAL OPERATION MANUAL For powering ICP sensors and in line charge converters this signal conditioner provides a cost effective method for powering small numbers of sensor channels The...

Page 7: ...2 Safety Considerations 1 1 3 Equipment Rating 2 1 4 Model 482C15 System Description 2 1 5 Model 482C05 System Description 4 1 6 Installation 4 1 7 Grounding Techniques 4 1 8 Unit Power 5 1 9 Maintena...

Page 8: ...heading used in this manual explains dangers that might result in personal injury or death Always read the associated information very carefully before performing the indicated procedure The CAUTION...

Page 9: ...ICP source current 0 to 20 mA Jumper selectable Voltage input mode Jumper selectable gain of x1 x10 x100 482C15 Only Lighted power indicator on the front panel Rear panel BNC input output connectors...

Page 10: ...he PC board Each channel can be set to your selected gain and other options The selection of all these features with jumpers allows the 482C15 to have the functionality of many other higher priced uni...

Page 11: ...that of most sensors and is close to an open circuit voltage of 26VDC The photo on the cover is shown with the unit on and no sensors attached so the OPEN LED is on The SHORT light indicates a very lo...

Page 12: ...plied with unit Plug the adapter into any 100 240VAC 47 63Hz power source attach the supplied ferrite clamp on the AC cord to ensure CE conformance and press the ON OFF button 1 7 2 Power Optional Aut...

Page 13: ...ctral Noise 10 Hz 0 60 V Hz 0 60 V Hz 4 Spectral Noise 100 Hz 0 22 V Hz 0 22 V Hz 4 Spectral Noise 1 kHz 0 22 V Hz 0 22 V Hz 4 Spectral Noise 10 kHz 0 19 V Hz 0 19 V Hz 4 Broadband Electrical Noise 1...

Page 14: ...003 005 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 25495 1 OF 1 5X MODEL 482C SERIES 4 CHANNEL SIGNAL CONDITIONER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 SMB 12 16 11 ECB 12 16 11 KEN L 12 16...

Reviews: