Model Number
356B41
TRIAX ICP® SEAT PAD ACCELEROMETER PER ISO 10326-1
Revision: B
ECN #: 38243
[4]
Performance
ENGLISH
SI
Sensitivity(± 10 %)
100 mV/g
10.2 mV/(m/s²)
Measurement Range
± 10 g pk
± 98 m/s² pk
Frequency Range(± 5 %)
0.5 to 1000 Hz
0.5 to 1000 Hz
[2]
Resonant Frequency
≥
27 kHz
≥
27 kHz
Broadband Resolution(1 to 10,000 Hz)
0.0002 g rms
0.002 m/s² rms
[1]
Non-Linearity
≤
1 %
≤
1 %
[3]
Transverse Sensitivity
≤
5 %
≤
5 %
Environmental
Overload Limit(Shock)
± 2000 g pk
± 19,620 m/s² pk
Temperature Range
+14 to 122 °F
-10 to 50 °C
Temperature Response
<0.10 %/°F
<0.17 %/°C
[1]
Electrical
Excitation Voltage
6.5 to 30 VDC
6.5 to 30 VDC
Constant Current Excitation
0.3 to 10 mA
0.3 to 10 mA
Output Impedance
≤
500 Ohm
≤
500 Ohm
Output Bias Voltage
2.8 to 4.5 VDC
2.8 to 4.5 VDC
Discharge Time Constant
1 to 3 sec
1 to 3 sec
Settling Time(within 10% of bias)
<20 sec
<20 sec
Spectral Noise(1 Hz)
50 µg/
√
Hz
490 (µm/sec
2
)/
√
Hz
[1]
Spectral Noise
(10 Hz)
10 µg/
√
Hz
98 (µm/sec
2
)/
√
Hz
[1]
Spectral Noise
(100 Hz)
4 µg/
√
Hz
39 (µm/sec
2
)/
√
Hz
[1]
Spectral Noise
(1 kHz)
2 µg/
√
Hz
20 (µm/sec
2
)/
√
Hz
[1]
Physical
Sensing Element
Ceramic
Ceramic
Sensing Geometry
Shear
Shear
Housing Material
Titanium
Titanium
Sealing
Hermetic
Hermetic
Size (Diameter x Width)
7.87 in x 0.472 in
200 mm x 12 mm
Weight
9.6 oz
272 gm
[1]
Electrical Connector
Integral Cable
Integral Cable
Electrical Connection Position
Side
Side
Cable Termination
1/4-28 4-Pin Jack
1/4-28 4-Pin Jack
Cable Length
5 ft
1.5 m
Cable Type
010 4-cond Shielded
010 4-cond Shielded
Mounting Thread
5-40 Female
5-40 Female
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
NOTES:
[1] Typical.
[2] Standard calibration to 100 Hz with sensor in mounting pad. Special calibration above 100 Hz
available with sensor outside mounting pad.
[3] Zero-based, least-squares, straight line method.
[4] See PCB Declaration of Conformance PS023 for details.
SUPPLIED ACCESSORIES:
Model 010G05 Cable (1)
Model 081A90 Mounting stud, 10-32 to 5-40 (1)
Model ACS-17 NIST Traceable amplitude and phase response calibration from 0.5 to 100 Hz.
Entered: DMW
Engineer: AJA
Sales: WDC
Approved: BAM
Spec Number:
Date: 2/3/2012
Date: 2/3/2012
Date: 2/3/2012
Date: 2/3/2012
33518
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-685-3886
E-Mail: [email protected]