PBI 86666 Instruction Manual Download Page 2

International pbi S.p.A   

Instruction Manual  

29/08/05              Rev. 1

 

2

INSTRUCTION MANUAL 

 

READ THIS BOOK CAREFULLY 

It is intended to help you operate and maintain your new instrument properly. 
Keep it handy for answers to your questions. 
 

IMPORTANT SAFETY INSTRUCTIONS 

When using this appliance, always exercise basic safety precautions, including the following:    
 

 

Use this appliance only for its intended purpose as described in this Use and Care book. 

 

This instrument must be properly installed in accordance with the Installation Instructions before it is used. 

 

Never unplug your instrument by pulling on the power cord. 

 

Always grip plug firmly and pull straight out from outlet. 

 

Repair or replace immediately all electric service cords that have become frayed or otherwise damaged. Do not 
use cord that shows cracks or abrasion damage along its length or at either the plug or connector end. 

 

When moving your instrument away from wall, be careful not to roll over or damage the power cord. 

 

Unplug your instrument: 

 

A. Before making any repair. 

 

Note: We strongly recommend that any servicing be performed by a qualified individual. 

 

B. Before cleaning. 

 

C. Before replacing any accessories. 

 

Do not operate your instrument in the presence of explosive fumes. 

 
When a standard two-prong wall outlet is encountered, it is your personal responsibility and obligation to have it 
replaced with a properly grounded three-prong wall outlet. 

 

Warning

 

 

Fire or electric shock hazard, do not  expose  this product to rain or moisture. 
This unit contains dangerous voltages.  NEVER remove cover unless qualified to do so 

 

CAUTION DURING INSTALLATION 

 

 

CAUTION 

 

This unit must be grounded. 
The power cord set provided is of the pattern often found in the market area, although 
this is by no means universal, but many other patterns are used around the world. 
If the plug is not compatible with the socket outlet available, it will be necessary to 
obtain a suitable alternative cord set with the correct  colour cables connection. The 
mains lead coloured green-and yellow must be connected to the ground terminal on the 
new plug which is marked with the letter or the earth symbol 

 or coloured green-and-

yellow. 

 

CAUTION 

 

 
Before connecting the instrument to a power supply check that the voltage and 
frequency details shown on the rear identification label are compatible with your main 
supply. 
N.B. The equipment must only be connected to a protectively grounded mains supply. 
In the event of any uncertainty it is recommended that a qualified electrician be 
consulted. 
 

 

CAUTION

 

If using a maine supply without a protective earth. Before plugging in the unit, the 
ground terminal close to the mains cable on the rear of the apparatus, must be connected 
via a 2,5 mm

2

 stranded wire to a safe earth. This work must be done by an authorised 

electrician. 

 

Prior to operation always ensure that the ventilation grids of the instrument are not 
obstructed and that it is not positioned directly against a wall. 

Summary of Contents for 86666

Page 1: ...PYRAMID Flowcheck System Code n 86666 I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L International PBI S p A Via Novara 89 20153 Milano Italy Tel 39 02 48779 1 Fax 39 02 40090010 International...

Page 2: ...y grounded three prong wall outlet Warning Fire or electric shock hazard do not expose this product to rain or moisture This unit contains dangerous voltages NEVER remove cover unless qualified to do...

Page 3: ...al 29 08 05 Rev 1 3 INDEX 1 Introduction pg 4 2 Technical specification pg 4 3 Component of the Pyramid system pg 5 4 Preliminary inspection pg 5 5 Installation pg 6 6 Operations pg 7 7 Maintenance pg...

Page 4: ...xact air flow that is passing through the fan The Pyramid flowcheck system can display the airflow either in litres per minutes L or cubic feet per minute CF The precision of the measured value is for...

Page 5: ...ded that this scientific system is treated with care and attention in order to maintain its precision 4 PRELIMINARY INSPECTION 4 The apparatus is subject to specific working tests before shipping and...

Page 6: ...ong surface Avoid current of air around the instrument 5 Program 1000 litres of air on the SAS air sampler and switch it on 6 Position the Pyramid system c on top of the SAS air sampler 7 Switch on th...

Page 7: ...ded that the system is carefully treated The system doesn t require special care and maintenance procedure Clean the outside surface with a normal cloth Do not subject the system to sudden shock Batte...

Page 8: ...EN KUNDEN F r Benutzer unserer Apparate sind alle ersatzteilen die sich aus mechanischen Fehlern in normalen Gerbrauch ergeben f r zen Monate garantiert Damit wir Ihnen einem erstklassigen Service die...

Page 9: ...TROL DATE INSTRUMENT MODEL DATE OF LAST CONTROL AVERAGE VALUE OF THE LAST CONTROL 55mm CONTACT PLATE RODAC 84mm CONTACT PLATE 90mm PETRI DISH TEST N 1 2 3 4 5 6 7 8 9 10 LTS MN TEMPERATURE LOCATION AV...

Page 10: ...KED TO THE EXPORT DPT Company Address City Zip Code State Phone Fax Email Name to contact Lab Division return request of technical service Equipment Model Serial Number for calibration repair other sp...

Page 11: ...International pbi S p A Instruction Manual 29 08 05 Rev 1 11...

Page 12: ...153 Milano HEREBY DECLARES under its sole responsibility that the following product PYRAMID Flowcheck System Art 86666 conforms with the technical requirements of the following directives 89 336 CEE 9...

Reviews: