2 4 V D C M o d e l s
Input
90-132 VAC @ 5.0 A
180-264 VAC @ 2.5 A
50/60 Hz
IEC 320-C14 Connection
Output
24 VDC, 8 Amps DC charging current
¨
Reverse polarity and short circuit-proof
¨
7 hour full charge, typical re-charge 3-6 hours
¨
20-100 hour typical battery duration
¨
Smart charging
Use only NRTL-listed (National Recognized Testing Lab)
accessories.
I n v e r t e r
Input Voltage
10.5 to 15VDC (12V)
21 to 30VDC (24V)
No Load Current
0.24A (12V)
0.28A (24V)
Frequency
60 Hz
Output Voltage
-5%
Output Power
300W RMS (continuous)
Surge Power
400W RMS (1 second)
Output Waveform
Pure Sine Wave (THD <6%)
Typical Efficiency
89%
Operating
Temperature
32
°
F to 105
°
F (0
°
C to 40
°
C)
Specifications