5 Configuration of the wibutler [specialist] 

6

 

991398735-mub-en – V01 

2017/01 

 

5

 

Configuration of the wibutler [specialist] 

1.

 

Set the Service Mode at the wibutler. The HeatBloC MC system is a wibutler 
Professional Product and can only be registered and designed, if the Service Mode is 
set. Please observe the separate instructions regarding the wibutler system. 

2.

 

Open the wibutler app and create all rooms for the heating circuits. 

3.

 

Start the teach-in process. Please observe the instructions in the wibutler app. 
  Teach-in process: 
  I.

 

Device management

 > Add (+) > select 

Manufacturer

 PAW > select product 

"HeatBloC MC" > start the teach-in process > follow the teach-in instructions in 
the app 

II.

 

Name the heating circuits and assign the heating circuits to the location of 
installation, f. ex. "Heating" > the Device Management section "PAW" displays 
all newly created heating circuits and the communication set 

 

Assignment of heating circuits and rooms (design) 

  I.

 

Settings

 > 

Service section

 > 

Heating control

 

II.

 

Heat distribution

 > 

Add heating circuit

 > name the heating circuit, f. ex. "1-ground 

floor" 

III.

 

> select the created heating circuit > configure the heating circuit (>) 

IV.

 

> select 

Control type

 and confirm > assign the rooms 

V.

 

> add 

Control-/Regulation modules

 > select the corresponding PAW heating 

circuit and confirm > select the selected heating circuit > navigate to the tab 

Options

 > set the minimum and maximum temperatures 

VI.

 

Check, if all rooms are assigned to this heating circuit. 

VII.

 

Create and configure further heating circuits. 

4.

 

Check the additionally assigned components such as room control unit and heat 
generation. 

5.

 

Assign the newly created heating circuits to the heating generator:  

Heating generation

 > 

Heating generator

 > 

Heating circuits

 > 

Add

 > select heating circuits 

6.

 

Delete all messages, that appeared in the wibutler app during installation.  
After commissioning the system works properly and these messages are out-of-date.  

7.

 

Set the normal mode at the wibutler. Please observe the separate instructions 
regarding the wibutler system. 

8.

 

Familarize the main user with the installation. 

 

Summary of Contents for Wibutler EnOcean Dongle

Page 1: ... Böcklerstr 11 D 31789 Hameln Germany Phone 49 5151 9856 0 Fax 49 5151 9856 98 E mail info paw eu Web www paw eu 2017 01 991398735 mub en V01 1 Assembly instructions wibutler EnOcean dongle for the HeatBloC MC system ...

Page 2: ... description 4 4 Assembly specialist 5 5 Configuration of the wibutler specialist 6 6 Deinstallation 7 7 Technical data 7 Item no 991398735 mub en Version V01 Issued 2017 01 Translation of the original instructions We reserve the right to make technical changes without notice Printed in Germany Copyright by PAW GmbH Co KG PAW GmbH Co KG Böcklerstr 11 D 31789 Hameln Germany ...

Page 3: ... the wibutler EnOcean dongle excludes any liability claims Only use original accessories with the wibutler EnOcean dongle The wrapping materials are made of recyclable materials and can be disposed of with recyclable materials 2 Safety instructions The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocati...

Page 4: ...ermits sending and receiving of radio messages remote configuration of the MC heating circuits within the scope of the wibutler app presetting of nominal temperatures sending of status values messages and error messages to the wibutler The dongle is connected to the communication set via the enclosed USB extension This product is subject to and complies with the Radio and Telecommunication Termina...

Page 5: ... according to the instructions 2 Open the PAW MCom app and start the hydraulic balancing of the radiators 3 Generate the commissioning certificate in the PAW MCom app 4 Shut down the communication set see controller instructions 5 Disconnect the HeatBloC MC system and the communication set from the power supply 6 Connect the dongle to the USB extension of the communication set 7 Establish the powe...

Page 6: ... design I Settings Service section Heating control II Heat distribution Add heating circuit name the heating circuit f ex 1 ground floor III select the created heating circuit configure the heating circuit IV select Control type and confirm assign the rooms V add Control Regulation modules select the corresponding PAW heating circuit and confirm select the selected heating circuit navigate to the ...

Page 7: ...egarding the communication set 7 Technical data USB power supply Type A Frequency 868 MHz Internal chip antenna R TT EN 300 220 CE RoHS yes Housing size 70 x 23 x 9 mm incl cap Weight 12 g Operating temperature 0 C 40 C non condensing Storage temperature 25 C 65 C Humidity during operation 0 80 non condensing Humidity during storage 0 93 relative humidity Status LEDs Power LED green Bus activity L...

Page 8: ...PAW GmbH Co KG Böcklerstraße 11 D 31789 Hameln Germany www paw eu Phone 49 0 5151 9856 0 Fax 49 0 5151 9856 98 991398735 mub en V01 2017 01 ...

Reviews: