Page 55
ALIBI MEMORY CONSULTATION
This menu only appears in case of METRIC functioning.
SUB MENU
MESSAGGE
NAME
DESCRIZIPTION
TYPE
RANGE
ALi.NEN
SEE.NEN.
Aliby
memory
consultation
Procedure for consulting weigh
stored in aliby memory.
Spc 0÷959999
In case of METRIC functioning and with aliby memory enabled:
• Each executed weigh is stored in the aliby memory.
• For each weighing it is associated an identification code, with value range from 0 to 959999
• The identification code of the weighing is transmitted to the serial port at the time of weighing.
ALIBI MEMORY CONSULTATION PROCEDURE
000000
Enter the ID code of the weighing and confirm with the PRG key.
0.000
The display shows the weight associated with the required identification code. Press the
DOWN
key to exit the consultation procedure of the alibi memory.
no Cod.
If the required identification code is not present in the alibi memory, a timed message “NO CODE” is
showed.
Summary of Contents for DAT11
Page 2: ...Page II ...
Page 83: ...Page 81 ...