background image

Paul  Wegener  GmbH 

 

 

 

 

 

 

 

 

 

         

10

Used electric appliances, batteries and rechargeable batteries are subject to particular statutory 

provisions. Batteries, rechargeable batteries and electric appliances must not be disposed with the 

household waste. The end user is obligated to return them by the law. Used electric appliances, 

batteries and rechargeable batteries can be disposed at collecting points, municipal disposal areas 

or by manufacturer / supplier. 

The Paul Wegener GmbH as seller of batteries and electric appliances fulfills its take-back obliga

-

tion and disposes used batteries and old electric appliances free of charge.
This take-back obligation, however, limits itself to used electric appliances, batteries and recharge-

able batteries which belong or belonged to the product range of the Paul Wegener GmbH and the 

amount which was delivered by the Paul Wegener GmbH.
The end user bears the forwarding charges.

Storage times of the internal memory result from the number of channels occupied, from preset 

sample intervals 1 and 2 as well as from storage and sample mode. If the reading resolution is > 8 

bit (12, 14 or 16 bit), possible storage times will halve themselves.

Non sparking        II3G Ex nA IIB T4 according to EN 60079-0 and EN 60079-15 for safe use within 

the explosion-hazard area of zone 2.

4.2 

Explosion protection (optional)

4.3 

Data memory

Recycling of batteries and old appliances

4.4 

Estimation of accumulator service life 

Following table contains accumulator durations depending on preset sample rate and based on 

following assumptions: 

• 

constant ambient temperature of 20°C

• 

constant power consumption of built-in components

• 

no capacity loss by aging of the accumulator

• 

no fault current due to defective components

As the above-mentioned exceptions are unrealistic, to be on the safe side, we assume 60% of the 

real accumulator capacity is provided only. For calculation, the underlying standby current of the 

system will be increased by factor 2. Though deviations (positive, negative) can not be excluded 

from mentioned duration! 

Sample rate in s

Battery service life in 

days

1

131

2

202

5

297

10

352

15

376

30

402

60

417

Summary of Contents for PWBlogg N6/40

Page 1: ...Operating manual Data acquisition system PWBlogg Type N6 40...

Page 2: ...llenstedt All rights reserved No section of the operating manual may be replicated or processed duplica ted or distributed using electronic systems in any way print photocopy microfilm or other me tho...

Page 3: ...repair All subsequent modifications to the device result in the consequence that a secure use is no more guaranteed within ex zone 2 and the EC declaration of conformity loses ist validity 3 Safety p...

Page 4: ...ters 6 2 2 Error sources 7 2 3 Data communication 7 3 Charging the built in accumulator 9 4 Technical specifications 9 4 1 Data logger 9 4 2 Explosion protection optional 10 4 3 Data memory 10 4 4 Est...

Page 5: ...r The measurement range begins at 50 mbar Data logger The data logger has an integrated analog digital converter with high resolution which is responsible for logging and digitizing pressure and tempe...

Page 6: ...resholds and records threshold violations by means of a se cond sample rate Additional to the threshold a hysteresis can be specified Important parameters to monitor thresholds are described as follow...

Page 7: ...s are non linearities of AD converter which are irrelevant on resolution of 8 bit or 12 bit However another important one is the digital step at small resolutions At the limit of two sequent digital v...

Page 8: ...8 Paul Wegener GmbH Performance data evaluation can be done in tabular form or as chart Individual periods can be enlarged by the integrated zoom function...

Page 9: ...in power saving mode If the accumulator s residual capacity falls below 20 then at the latest it should be recharged We recommend 100 charging prior to any operation The accumulator must not be replac...

Page 10: ...umber of channels occupied from preset sample intervals 1 and 2 as well as from storage and sample mode If the reading resolution is 8 bit 12 14 or 16 bit possible storage times will halve themselves...

Page 11: ...business and trade as well as small firms EN 61000 6 2 subject standard for interference resistance industrial sector EN 60079 0 electrical equipment for explosion hazard areas section 0 general requi...

Page 12: ...umulator is low Have it replaced by manufacturer Password forgotten Read out performance data send reading file to manufacturer Software does not read per formance data comple tely or reports errors w...

Page 13: ...Operating manual of data acquisition system PWBlogg 13...

Page 14: ...14 Paul Wegener GmbH...

Page 15: ...Operating manual of data acquisition system PWBlogg 15...

Page 16: ...r GmbH Tel Fax Internet e mail 49 0 39483 96 300 49 0 39483 96 400 www paul wegener de info paul wegener de Most recent emendment 01 08 2013 PWB FORM 2085 EN13 Paul Wegener GmbH Marienstra e 24 D 0649...

Reviews: