55
Troubleshooting
Light
Description
Action
P25, P35, P70:
A green pulse
every 1.5 sec.
P140:
During the day a
green pulse every
1.5 sec. at night
every 2 sec.
Your energizer is ready for use!
No further action needed.
A green pulse
every
3.5 sec.
This is part of the normal battery save cycle.
The energizer battery may be low.
A red pulse
Place energizer in direct sunlight to charge the
battery. If a red pulse persists after three days,
contact your local representative to arrange
testing by an approved service agent.
A solid red light
The energizer is not outputting pulses to the
fence. Contact your local representative to
arrange testing by an approved service agent.
No lights are on
Either the battery is not connected properly, or
the battery is dead. Remove the energizer out
of the direct sun, open the energizer and dis-
connect the battery. Reconnect the battery and
face the energizer towards the sun to charge
the battery. If the issue persists, contact your
local representative to arrange testing by an
approved service agent.
Summary of Contents for P25 Solar