patura EBL20-12027 Installation Instructions Manual Download Page 9

Montageanleitung 

/ Instructions de montage

Installation Instructions / Montagehandleiding
Indicaciones de montaje

Operation of the device: 

1.  Connection to the battery: Close the red terminal of the charger to the positive terminal ( + ) of the battery and 

the black terminal at the negative terminal ( - ) of the battery.

2.  Connection to main cable: Connect the charger to the 230 V Ac mains (socket). The device is short-circuit  

proof! Longer lasting short-circuits (longer than one minute) must be avoided in any case, as otherwise the 
transformer or the power electronics is overloaded.

Attention!

- When charging batteries, make sure that the polarity of the battery is correct.
-  In order to avoid damage to the batteries, it is essential to ensure that the batteries are never deep discharged 

(more than 100% discharged).

- Ensure sufficient ventilation of the room during the charging process.
- Open the cell plugs of the lead acid battery.
- Check the acid level of the lead acid battery before charging.
- If charging for a longer period, also check the acid level occasionally.
-  Always avoid open fire, open light, and sparks in the vicinity of the straight batteries to be charged  

(Danger of explosion due to oxyhydrogen gas.)

-  It is imperative that you observe the charging instructions of the respective battery manufacturer  

(Mostly imprinted on the battery.)

Malfunction: 

If it can be assumed that safe operation is no longer possible, the device must be taken out of service and secu-
red against unintentional operation.
This applies under the following circumstances:  

- If the device shows visible damage.

 

   

 

 

 

 

- If the device is no longer functional.

 

   

 

 

 

 

- If parts of the device are loose or missing.

 

   

 

 

 

 

- If the connecting lines show visible damage.

If the device has to be repaired, only original spare parts may be used! The use of different spare parts can lead 
to serious damage to property and personal injury!
If the device should fail, we recommend that you send your device for repair to us.

Technical Data:

Charger type: 

EBL20 - 12027

Charging characteristic: 

IUoU

Mains connection: 

230V AC, 50 Hz

Nominal battery voltage: 

12V

Max. charging current: 

2.7A

U

1

 with recharging: 

14.7V

U

2

 - Float charge 

13.8V

Summary of Contents for EBL20-12027

Page 1: ...ht Lebensgefahr Der Betrieb unter widrigen Umgebungsbedingungen ist unter allen Umst nden zu vermeiden Widrige Umgebungsbedingungen sind Umgebungstemperaturen ber 50 C brennbare Gase L sungsmittel D m...

Page 2: ...nung hat 14 70 V erreicht Es wird ca 2 Std mit stetig sinkendem Ladestrom geladen siehe Diagramm gr n Der Ladevorgang ist abgeschlossen und das Ger t befindet sich im Modus Erhaltungsladung 13 80 V Ak...

Page 3: ...auch zwischendurch den S urestand Vermeiden Sie grunds tzlich offenes Feuer offenes Licht und Funken in der N he der gerade zu ladenden Akkus Explosionsgefahr durch Knallgas Beachten Sie unbedingt di...

Page 4: ...mbiante sup rieure 50 C l exposition du gaz inflammable des solvants la vapeur ou bien la poussi re ou encore l humidit tout comme une humidit atmosph rique d passant les 80 L appareil ne doit tre uti...

Page 5: ...14 70V Elle se charge alors pendant environ 2 heures avec un courant de charge qui diminue constamment voir le diagramme Vert Le processus de charge est termin et l appareil atteint mode charge d entr...

Page 6: ...tout risque de feu de lumi re et d tincelles proximit des piles rechargeables risque d explosion d aux gaz d tonnants Il est essentiel de respecter les instructions de chargement du fabricant de la b...

Page 7: ...rcumstances Adverse environmental conditions include Ambient temperatures above 50 C flammable gases solvents vapors dust humidity above 80 rel and moisture The device may only be operated in dry and...

Page 8: ...device charges with maximum current Yellow Timer mode the battery voltage has reached 14 70 V Approx 2 hrs is used with continuous charge current See diagram Green The charging process is complete and...

Page 9: ...ng If charging for a longer period also check the acid level occasionally Always avoid open fire open light and sparks in the vicinity of the straight batteries to be charged Danger of explosion due t...

Page 10: ...zichtig levensgevaar Het gebruik bij ongunstige omgevingsfactoren moet te allen tijde worden vermeden Ongunstige omgevingsfactoren zijn Omgevingstemperaturen boven 50 C brandbare gassen oplosmiddelen...

Page 11: ...maximale stroomsterkte Geel Timer modus De accuspanning heeft 14 70 V bereikt De lading gebeurt ca 2 uur lang met een gestaag afnemende laadstroom zie diagram Groen Het laadproces is voltooid en het a...

Page 12: ...sendoor Vermijd altijd vuur open vlammen en vonken in de buurt van de accu s die worden opgeladen explosiegevaar door knalgas Houd u strikt aan de oplaadinstructies van de desbetreffende accufabrikant...

Page 13: ...a exposici n a gases inflamables disolventes vapor o al polvo o a la humedad as como a la humedad atmosf rica superior al 80 El cargador s lo debe usarse en reas secas y cerradas Si se considera que y...

Page 14: ...continuaci n se carga alrededor de 2 horas con una corriente de carga en constante disminuci n ver diagrama Verde El proceso de carga ha finalizado y la unidad alcanza el modo de carga de mantenimient...

Page 15: ...vez en cuando en caso de una carga prolongada Evite cualquier riesgo de incendio luz y chispas cerca de las bater as recargables riesgo de explosi n debido a los gases detonantes Es esencial cumplir c...

Page 16: ...de montage Installation Instructions Montagehandleiding Indicaciones de montaje PATURA KG Germany Tel 00 49 93 72 94 74 0 www patura com Mainblick 1 63925 Laudenbach Fax 00 49 93 72 94 74 29 info pat...

Reviews: