Five options of frost protection

1. Heating element 24 V, for installation into the trough

(see separate mounting instructions)
Heating element 24 V, 180 W (131.6063) for installation into the trough.

131.6063

2. Heating element 24 V, for installation under the trough

(see separate mounting instructions)
Heating element 24 V (131.6060, 131.6061, 131.6062) for installation under the trough. For power supply a SUEVIA Transformer 230/24 V is 
necessary. For automatic switch on/off of transformer a thermostat (101.0389) can be additionally installed. To ensure a frost-free feed pipe, a frost 
protection heating cable 24 V, 20 W, 2 m (101.0861), or a 24 V, 30 W, 3 m (101.1863) has to be used. The heating cable should be wrapped around 
the pipe and connected to the heating element of the drinker in parallel to the power supply cable, coming from the transformer. If this heating cable 
is installed on plastic pipes, make sure that this water pipe is suited for warm and cold water. For better heat distribution the water pipe has to be 
wrapped first with an aluminium adhesive tape (101.1099). The frost protection heating cable and the supply line should be protected against animal 
bites or other damages.

131.6062

131.6061

131.6060

3. Connection to a water circuit with a circuit pipe

¾" circuit pipe (131.6064) or 1" circuit pipe (131.6110, 131.6111, 131.6112, 131.6113) suited for installation into quick drainage troughs 
(manufactured as of 12.2014). Frost protection is reached for the water line as well as for the water in the trough, if connected to a water circuit with 
a SUEVIA heating unit.

131.6064

131.6110 · 131.6111 · 131.6112 · 131.6113

1"

¾"

¾"

¾"

101.0861
101.1863

131.6064

131.6110
131.6111
131.6112
131.6113

131.6063

Summary of Contents for 130.6714

Page 1: ...any Montageanleitung Mounting Instructions Instructions de montage Deutsch English Fran ais 130 6714 130 6719 130 6723 130 6728 DE Montageanleitung Schnellablauf Trog Wasserdruck max 5 bar Mounting In...

Page 2: ...reserv s 104 8198 Deutsch English Fran ais Zubeh r Accessories Accessoires Mod 6714 131 6060 Mod 6719 131 6061 Mod 6723 131 6062 Mod 6728 131 6062 131 6090 131 0521 131 6067 131 6063 131 6031 101 086...

Page 3: ...iste 4 Montage 5 Abma e 6 7 F nf M glichkeiten f r einen erh hten Frostschutz 8 Einregulieren des Wasserstandes Page Contents 2 Spare Parts 9 Mounting 10 Dimensions 11 12 Five options of frost protect...

Page 4: ...Es sollte ein Wasserfilter 101 0487 vor dem Schwimmer ventil eingebaut werden Optional nur wenn extra bestellt 6 Frostschutzw chter 131 0521 montieren siehe separate Montageanleitung 7 Zusatzheizung...

Page 5: ...m 325 l 150 463 13 900 82 75 75 75 150 130 6714 1305 130 6719 1800 130 6723 2220 130 6728 2780 75 13 63 Zur Befestigung des Troges an einer Wand aus Holz oder Beton sind 6 durch gehende Schrauben erfo...

Page 6: ...ng wird diese parallel mit der vom Transformator kommenden Stromzuleitung an der Heizspirale der Tr nkewanne angeschlossen Wird die Frostschutz Heizleitung auf Kunststoff Leitungen verlegt achten Sie...

Page 7: ...s Wasser vom Frostschutzw chter flie t durch die Bohrung im Ablaufstopfen ab siehe Montageanleitung 131 0521 Optionale Erweitung Durch den zus tzlichen Einbau von einem Niederdruck Schwimmerventil 130...

Page 8: ...3 steht Wasserdruck max 5 bar m glich H henverstellung Max Leitungsl ngen Querschnitt z B Type NYY bis 100 Watt bis 200 Watt bis 300 Watt bis 400 Watt 2 5 mm 83 m 42 m 28 m 21 m 4 0 mm 132 m 66 m 44 m...

Page 9: ...er sand suspended matters is given SUEVIA preliminary filter 101 0487 must be installed before the trough drinker Optional 6 Fix the frost protection guard see an additional mounting instructions 7 Fi...

Page 10: ...2 4150 mm 325 l 150 463 13 900 82 75 75 75 150 130 6714 1305 130 6719 1800 130 6723 2220 130 6728 2780 75 13 63 For fixation of the trough to the wooden or concrete wall 6 continuous bolts are necessa...

Page 11: ...d The heating cable should be wrapped around the pipe and connected to the heating element of the drinker in parallel to the power supply cable coming from the transformer If this heating cable is ins...

Page 12: ...rost the installed and adjusted frost protection guard opens automatically the adjusted water quantity flows into the troughover the float valve situated under the frost protection guard water in the...

Page 13: ...gle to the valve lever 102 0393 Water pressure max 5 bar 73 psi Height adjustment Increased frost protection of the valve For extremely cold areas subsequent installation of a valve heating model 527...

Page 14: ...d installer un filtre 101 0487 en d but de ligne En option 6 Installer le Kit flotteur antigel voir les instructions de montage correspondantes 7 Installez la r sistance L alimentation lectrique de l...

Page 15: ...150 463 13 900 82 75 75 75 150 130 6714 1305 130 6719 1800 130 6723 2220 130 6728 2780 75 13 63 Pour la fixation de l abreuvoir au mur en bois ou en b ton 6 vis sont n ces saires Percement des trous...

Page 16: ...e au trans formateur se fait parall lement avec la r sistance de l abreuvoir Si l installation d un c ble chauffant devait se faire sur un tuyau en PE bien v rifier que le PE soit pr vu pour de l eau...

Page 17: ...uvre automatiquement en cas de gel et fait couler un filet d eau sur le flotteur situ en dessous Le volume d coulement est r glable selon l intensit du gel L coulement continu du robinet du kit flotte...

Page 18: ...pe 102 0393 Pression maximum 5 bar Protection antigel lev e pour la soupape Pour les r gions ayant des hivers rigoureux une manchette chauffante pour la soupape mod le 527 131 0527 24 V 7 W peut tre i...

Page 19: ...ged without prior notice Des changements techniques reserv s 104 8198 7 1 2 1 3 5 10 7 230 V 24 V C IP54 IP44 11 9 8 6 4 SUEVIA 1 e 2 3 DN 125 4 5 DIN 1988 DIN EN 1717 5 101 0487 6 7 8 131 6090 9 131...

Page 20: ...ngements techniques reserv s 104 8198 mm 140 1030 940 130 6714 1400 mm 100 l 130 6719 1900 mm 130 l 130 6723 2300 mm 160 l 130 6728 2850 mm 200 l 130 6742 4150 mm 325 l 150 463 13 900 82 75 75 75 150...

Page 21: ...4 8198 1 24 24 131 6063 131 6063 2 24 24 131 6060 131 6061 131 6062 SUEVIA 230 24 101 0389 24 2 20 101 0861 3 30 101 0863 101 1099 131 6062 131 6061 131 6060 3 131 6064 1 131 6110 131 6111 131 6112 13...

Page 22: ...lten Technical data can be changed without prior notice Des changements techniques reserv s 104 8198 4 1 3 1 5 SUEVIA 131 0521 131 0738 6064 MAXIFLOW 131 0700 131 6090 131 0521 131 0521 131 0723 131 6...

Page 23: ...can be changed without prior notice Des changements techniques reserv s 104 8198 1 2 102 0621 3 3 102 0621 90 102 0393 5 527 131 0527 24 7 131 0527 Type NYY 100 200 300 400 2 5 83 42 28 21 4 0 132 66...

Reviews: