SmartNode 10100A Series Quick Start Guide

5

Note

Ethernet ports (ETH 0/0 & 0/1), and SMS ports (SMS-0/0 & 0/1) are not used 
when connecting VoIP.

Figure 2. 

Connecting the VoIP ports

4.0  Connecting to the PSTN

A SN10100A with 8 RJ48C type ports enables the connection to T1/E1 lines.

Note

T1/E1 ports are activated by software license; the number of active ports 
depends on the licenses purchased.

   1.

Start with port 0, located at the top and leftmost position. Connect one cable 
between this port and the T1/E1 line.

   2.

Repeat step 1, using the next available port 

Figure 3. 

Port Interface to the PSTN

5.0  Grounding the Equipment Chassis

As a standard safety practice, the chassis of the SN10100A series gateway must be 
properly grounded to protect against any contact with an electrical fault condition. It is 
recommended that the chassis be connected to an earth ground. If the SN10100A 
series gateway is mounted in an equipment rack, then the ground cable must be con-
nected from the ground lug of the SN10100A series gateway ground to the ground bar 
of the equipment rack. If more than one SN10100A series gateway is installed in an 
equipment rack, each SN10100A series gateway must be grounded directly to the 
equipment rack ground bar.

VoIP Netwo

r

k 1

15

14

13

12

10 11

8

9

3

2

0

7

6

5

4

1

MGMT0

MGMT1

ETH0

ETH1

VOIP0

VOIP1

VoIP Netwo

r

k 2

15

14

13

12

10 11

8

9

3

2

0

7

6

5

4

1

MGMT0

MGMT1

ETH0

ETH1

VOIP0

VOIP1

16-Po

r

t I

n

te

r

face to the P

S

TN

Summary of Contents for SmartNode SN10100A Series

Page 1: ...Start Guide Important This is a Class A device and is not intended for use in a residential environment Part Number 07MSN10100 QS Rev C Revised August 24 2018 Sales Office 1 301 975 1000 Technical Sup...

Page 2: ...are rated for proper voltage current anticipated temperature flamma bility and mechanical serviceability WAN LAN PSTN ports connections may have hazardous volt ages present regardless of whether the d...

Page 3: ...r Entflammbarkeit und mechanische Wartbarkeit geeignet sind WAN LAN u PSTN Ports Anschl sse k nnen unter gef hrlicher Spannung stehen unabh ngig davon ob das Ger t ein oder ausges chaltet ist PSTN bez...

Page 4: ...packing slip One SmartNode SN10100A Series Quick Start Guide One SmartNode SN10100A Important Notice sheet with unique information for your specific unit 2 0 Installing the rack hardware 1 Install ra...

Page 5: ...Chassis As a standard safety practice the chassis of the SN10100A series gateway must be properly grounded to protect against any contact with an electrical fault condition It is recommended that the...

Page 6: ...nd lug of the SN10100 series gate way See figure 4 2 Connect the other end of the ground wire to a ground bar of the equipment rack If the SN10100 series gateway is not installed in an equipment rack...

Page 7: ...terface see 7 2 Connecting the Ethernet management interface on page 8 The IP address of the management port is 192 168 200 10 24 If it is not possible to connect to the management port via IP use the...

Page 8: ...e serial port 7 2 Connecting the Ethernet management interface 1 Connect the supplied CAT5 Ethernet cable to the management port labeled MGMT0 on the rear of the SmartNode 10100A see figure 8 on page...

Page 9: ...c credentials included on the Important Notice that shipped with your unit If you do not have the Important Notice sheet contact support patton com 8 2 Accessing the SmartNode via the Ethernet Managem...

Page 10: ...t Management port on page 9 9 1 Connecting to the web server Using a web browser connect to the Web Portal by typing the following in your address bar http DEVICE HOST NAME 12358 or alternately http D...

Page 11: ...tee that interference will not occur in a particular installation If the equipment causes interference to radio or television reception which can be deter mined by disconnecting the cables try to corr...

Page 12: ...41 0 31 985 25 55 Switzerland Monday Friday 9 00 am to 5 30 pm CET 08 00 to 16 30 UTC GMT Fax 1 253 663 5693 USA or 41 0 31 985 25 26 Switzerland Copyright statement Copyright 2013 2018 Patton Electro...

Reviews: