SmartNode 10100A Series Quick Start Guide
5
Note
Ethernet ports (ETH 0/0 & 0/1), and SMS ports (SMS-0/0 & 0/1) are not used
when connecting VoIP.
Figure 2.
Connecting the VoIP ports
4.0 Connecting to the PSTN
A SN10100A with 8 RJ48C type ports enables the connection to T1/E1 lines.
Note
T1/E1 ports are activated by software license; the number of active ports
depends on the licenses purchased.
1.
Start with port 0, located at the top and leftmost position. Connect one cable
between this port and the T1/E1 line.
2.
Repeat step 1, using the next available port
Figure 3.
Port Interface to the PSTN
5.0 Grounding the Equipment Chassis
As a standard safety practice, the chassis of the SN10100A series gateway must be
properly grounded to protect against any contact with an electrical fault condition. It is
recommended that the chassis be connected to an earth ground. If the SN10100A
series gateway is mounted in an equipment rack, then the ground cable must be con-
nected from the ground lug of the SN10100A series gateway ground to the ground bar
of the equipment rack. If more than one SN10100A series gateway is installed in an
equipment rack, each SN10100A series gateway must be grounded directly to the
equipment rack ground bar.
VoIP Netwo
r
k 1
15
14
13
12
10 11
8
9
3
2
0
7
6
5
4
1
MGMT0
MGMT1
ETH0
ETH1
VOIP0
VOIP1
VoIP Netwo
r
k 2
15
14
13
12
10 11
8
9
3
2
0
7
6
5
4
1
MGMT0
MGMT1
ETH0
ETH1
VOIP0
VOIP1
16-Po
r
t I
n
te
r
face to the P
S
TN