Power and power supply specifications
39
CopperLink Model 1300R Series User Manual
B • Specifications
Power and power supply specifications
The CL1300R Series comes with either an AC or DC power supply:
•
The power connection to the CL1314R is a terminal block (see
Figure 9
).
•
There is one fuse in the equipment rated at 250V, 500 mA, 2 sec.
•
Rated voltage: 5 VDC
•
Rated current: 1 A DC
Figure 9. Terminal block power connection
External AC universal power supply
•
Output from power supply: 5 VDC, 2A
•
Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
External 48 VDC power supply
•
Input
-
Rated voltage: 36–60 VDC
-
Rated current: 0.25 A DC
•
Output
-
Rated voltage: 5 VDC ± 5%, 5W
-
Rated current: 1 A DC
-
6-inch cable terminated with 2.5 mm barrel plug, center positive
•
Isolation: 500 VDC
•
Environment: 0–40°C; 5–95% relative humidity, non-condensing
The external AC adapter shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. Ensure that the AC power
cable meets all applicable standards for the country in which it is
to be installed, and that it is connected to a wall outlet which has
earth ground.
The external DC adapter shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. The interconnecting cables
shall be rated for the proper voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability
Power
+ -
CAUTION
CAUTION