Power input connector
15
CopperLink Model 1300R Series User Manual
1 • General information
Power input connector
The CopperLink comes with an AC or DC power supply. (See section
“Power and power supply specifica-
tions”
on page 39.)
•
The power connection to the CL1300R is a terminal block (see
Figure 2
).
•
Rated voltage: 5 VDC
Rated current: 1 A
Figure 2. Terminal block power connection
External AC universal power supply
For additional specifications, see section
“Power and power supply specifications”
on page 39.
•
Output from power supply: 5 VDC, 2 A
•
Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
External 48 VDC power supply
Refer to section
“Power and power supply specifications”
on page 39 for additional specifications.
•
Input
-
Rated voltage: 36–60 VDC
-
Rated current: 0.25 A DC
-
3-pin locking connector, 3.5 mm pitch
-
Transient over-voltage protection, 100VDC at 2 ms
•
Output
-
Rated voltage: 5 VDC ± 5%, 5W
-
Rated current; 1 A DC
The external AC adapter shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. Ensure that the AC power
cable meets all applicable standards for the country in which it is
to be installed, and that it is connected to a wall outlet which has
earth ground.
The external DC adapter shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. The interconnecting cables
shall be rated for the proper voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability
Power
+ -
CAUTION
CAUTION