Line Framing Options:

D4/Superframe:  The D4 framing format, as specified in AT&T

TR62411 is the standard in which twelve frames make up a
superframe. All signaling and synchronization are done in-
band.

Extended Superframe (ESF):  Extended Superframe, as speci-

fied in AT&T TR 54016, consists of twenty-four (24) T1
frames.  The framing bits are now used for framing, CRC and
the Facility Data Link (FDL).  The FDL allows maintenance
messages and information to be passed between the 2720
and the Central Office.

Line Coding Options:

Alternate Mark Inversion (AMI):  This mode does not inherently

account for ones density.  To meet this requirement, each time
slot can be reduced to 56 kbps and the Least Significant Bit
(LSB) of each time slot set to one.

Bipolar 8 Zero Substitution (B8ZS):  This mode assures proper

bit density in the data stream.  In this mode any data pattern
can be transmitted without causing ones density errors.  This
mode allows for 64 kbps clear channel timeslots.

Switch S2-5: DS0 Channel Rate

Use Switch S2-5 to set the DS0 rate.

SW2-5

Setting

Off

56 kbps

On

64 kbps

3.1.1  Switch S2

The table below shows the default configurations for Switch S2.  A

description of all S2 options follows this table.

Switches S2-1, S2-2, and S2-3

Use Switches S2-1, S2-2 and S2-3 to set the DTE data rate.

Each setting represents an nx56/nx64 setting. Individual channel set-
tings can be configured through the software control port.  

S2-1

S2-2

S2-3

Speed

Off

Off

Off

Clear Channel (Unframed)

On

Off

Off

112kbps/128kbps

Off

On

Off

224kbps/256kbps

On

On

Off

336kbps/384kbps

Off

Off

On

448kbps/512kbps

On

Off

On

672kbps/768kbps

Off

On

On

896kbps/1024kbps

On

On

On

1344kbps/1536kbps

Switch S2-4: Line Framing and Coding

Use Switch S2-4 to control the Network Line Framing and Coding

Options.  Set these options to be the same as the Line Framing and
Coding Options given to you by your Service Provider.  If you are using
two Model 2720s together as short range modems, set both units iden-
tically.

S2-4

Line Framing & Coding

Off

ESF/B8ZS

On

D4/AMI

9

10

S2 SUMMARY TABLE

Position

Function

Factory Default

Selected Option

S2-1

Data Rate

On

S2-2

Data Rate

On

S2-3

Data Rate

On

S2-4

Framing & Coding

Off

S2-5

DS0 Rate

On

S2-6

Clock Mode

Off

S2-7

Clock Mode

Off

S2-8

Reserved

Off

1.536 Mbps

(DTE Rate)

ESF/B8ZS

64 kbps

Network

Reserved

Network

Summary of Contents for NetLink 2720 Series

Page 1: ...I T1 Fractional T1 CSU DSU with Ethernet Bridging SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2720 I A Doc 086181UA Revised 04 11 01 C E R T I F I E D An ISO...

Page 2: ...m as warranted your sole recourse shall be repair or replacement as described above Under no con dition shall Patton Electronics be liable for any damages incurred by the use of this product These dam...

Page 3: ...ct you in advance If you elect to do so you have the right to file a complaint with the FCC If you have any trouble operating the Model 2720 Series please contact Patton Electronics Technical Support...

Page 4: ...atures that make sys tem setup easy The Ethernet Bridge in this unit requires no configura tion at all The NetLink T1 provides T1 terminations over a modular RJ 48C jack and comply with jitter toleran...

Page 5: ...al Cisco router with a serial interface configured as a PPP Half Bridge The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote Ethernet network...

Page 6: ...s On 64 kbps 3 1 1 Switch S2 The table below shows the default configurations for Switch S2 A description of all S2 options follows this table Switches S2 1 S2 2 and S2 3 Use Switches S2 1 S2 2 and S2...

Page 7: ...ck your clock mode settings and Tx Clock Invert S1 3 settings Switch S2 8 Reserved 3 1 2 Switch S1 The chart below shows the default configurations for Switch S1 A description of all S1 options follow...

Page 8: ...operating parameters Follow the instructions below to configure the Model 2720 using the software selections 1 Plug the 9 pin male end of the cable to your terminal or com puter s DB 9 serial port and...

Page 9: ...each letter you type The maximum length of the password which can include any character the terminal can generate is 16 characters 6 The Model 2720 will then display the Main Menu screen 3 2 1 Introd...

Page 10: ...isfaction you can save the changes permanently by exe cuting the Save Changes command This will update the unit s configuration and save all the parameters to permanent mem ory Logoff For security log...

Page 11: ...ring of the network interface performance over the Facility Data Link FDL AT T TR 62411 says the Extended Superframe Format extends the DS1 superframe structure from 12 to 24 frames for a total of 463...

Page 12: ...PRMs The messages con tain the NI performance over the last four seconds Thus up to three consecutive messages may be lost without loss of information It is available only with ESF When ANSI T1 403 is...

Page 13: ...the line The duration of the loopback is limited by the loopback timeout setting See Unit Operations paragraph 3 2 4 on pages 32 and 33 Default Config Source Switch default Option EEPROM Switch The Mo...

Page 14: ...al DTE The Model 2720 Initiating a RL can be in one of the following states Idle No user controlled loopbacks are active TxPr The Model 2720 is sending the preparatory phase pattern lasting for approx...

Page 15: ...the eight status messages Excessive zeros EXZ i e lack of pulses detected This condition may occur if the unit is not connected to the network in which case the EXZ is displayed continuously If EXZ co...

Page 16: ...hot of the link performance To clear all counters press the Backspace key If your keyboard does not have this key you can press a two key combi nation to affect the same result Hold down the Ctrl key...

Page 17: ...n minutes 00 30 thirty minutes default setting 00 45 forty five minutes 01 00 one hour 01 30 90 minutes 02 00 two hours 03 00 three hours NEVER forever the unit will remain in loopback without user in...

Page 18: ...Port 10Base T Hub RJ 45 Pin No RJ 45 Pin No 1 TD 1 RD 2 TD 2 RD 3 RD 3 TD 6 RD 6 TD 4 3 T1 FT1 INTERFACE CONNECTION The Network Line Interface Line is an eight position keyed modu lar jack configured...

Page 19: ...e s not octet aligned 7 pulses WAN receive frame s aborted 8 pulses Detected WAN receive frame s with CRC 9 pulses Detected LAN receive frame s too large 10 pulses Detected LAN receive frame s not oct...

Page 20: ...RL The Remote Digital Loopback RL test checks the performance of both the local and remote NetLink T1 as well as the communication link between them Any characters sent to the remote NetLink T1 in thi...

Page 21: ...h the LAL and RDL tests to evaluate the unit s and the communication links When a 511 2047 or QRSS test is invoked the NetLink T1 generates a pseudo random bit pattern of 511 bits 2047 bits or 2 20 bi...

Page 22: ...47 QRSS Standards AT T TR62411 TR54016 ANSI T1 403 Power Supply 120VAC 60 Hz to 5VDC 300mA wall mount transformer or UI 100 240VAC 50 60 Hz to 5 VDC 2A desktop trans former Dimensions 3 5 L x 2 1 W x...

Page 23: ...SSIGNMENT RJ 48C T1 DS0 Network Interface Female Modular Jack Pin Signal 1 RX Data TIP 1 2 RX Data RING1 4 TX Data TIP 5 TX Data RING TRS Jack RS 232 Control Port Pin Signal Direction Tip Tx Data From...

Reviews: