5.2  LOOP (V.54 & TELCO) DIAGNOSTICS

The NetLink-T1™ offers three V.54 loop diagnostics and is com-

patible with two Telco loop diagnostics.  Use these diagnostics to test
the CSU/DSU and any communication links.  These tests can be acti-
vated via the software control port (See Section 3.2.3  System
Diagnostics
), via signals on the serial port interface or the front panel
switch.  

5.2.1  Operating Local Loopback (LL)

The Local Loopback (LL) test checks the operation of the local

NetLink-T1™, and is performed separately on each unit.  Any data
sent to the local NetLink-T1™ in this test mode will be echoed
(returned) back to the user device (i.e., characters typed on the key-
board of a terminal will appear on the terminal screen).  

To perform a LL test, follow these steps:

1.

Activate LL.  This may be done in one of  two ways:

a.  Enter        Local Loop from the System

Diagnostics/Statistics menu and toggle the <Spacebar>
until “LL” appears next to the 

Local Loop option.

b.   Toggle the front panel switch to the “Local” position.

2.

Verify that the data terminal equipment is operating properly 
and can be used for a test. 

3.   Perform a V.52 BER (bit error rate) test as described in

Section 5.3.  If the BER test equipment indicates no faults,
but the data terminal indicates a fault, follow the manufactur-
er’s checkout procedures for the data terminal.  Also, check
the interface cable between the terminal and the NetLink-T1.

38

5.2.2   Operating Remote Digital Loopback (RL)

The Remote Digital Loopback (RL) test checks the performance of

both the local and remote NetLink-T1™, as well as the communication
link between them.  Any characters sent to the remote NetLink-T1™ in
this test mode will be returned back to the originating device (i.e, char-
acters typed on the keyboard of the local terminal will appear on the
local terminal screen after having been passed to the remote NetLink-
T1™ and looped back). 

There are two Remote Loops that can be initiated from the

NetLink-T1 unit: (1) V.54 Loop, and; (2) CSU Loop. The user can
select the type of  loop that can be initiated from the System
Diagnostics/Statistics 
screen or with Switch S1-1. When a loopback
is initiated this is the type of loop that the unit uses to loop up the
remote unit. NOTE:  The NetLink-T1 will respond to both loops regard-
less of the state of the RDL Type.

To perform an RDL test, follow these steps:

1.   Activate RDL.  This may be done in two ways:  

a.

Enter        Remote Loop from the System
Diagnostics/Statistics menu and toggle the <Spacebar>
until “RL” appears next to the 

Remote Loop option.; 

b.   Set the front panel switch to ‘Remote’.  

37

Figure 8. Local Loopback 

Ethernet

Device

Ethernet

Device

Receive

Recover

Clocking

Internal

Clocking

Cable Span

T1/FT1 CSU/DSU

Model 2720/I

T1/FT1 CSU/DSU

Model 2720/I

Clock/
Data

Clock/
Data

Clock/
Data

Data

Data

Model 2720/X

Model 2720/I 

LLB Initiated

Figure 9. Local Loopback 

Ethernet

Device

Ethernet

Device

Receive

Recover

Clocking

Internal

Clocking

Cable Span

T1/FT1 CSU/DSU

Model 2720/I

T1/FT1 CSU/DSU

Model 2720/I

Clock/
Data

Clock/
Data

Clock/
Data

Data

Data

Model 2720/I

RL Initiated

Model 2720/I 

b

b

a

a

x

Summary of Contents for NetLink 2720 Series

Page 1: ...I T1 Fractional T1 CSU DSU with Ethernet Bridging SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2720 I A Doc 086181UA Revised 04 11 01 C E R T I F I E D An ISO...

Page 2: ...m as warranted your sole recourse shall be repair or replacement as described above Under no con dition shall Patton Electronics be liable for any damages incurred by the use of this product These dam...

Page 3: ...ct you in advance If you elect to do so you have the right to file a complaint with the FCC If you have any trouble operating the Model 2720 Series please contact Patton Electronics Technical Support...

Page 4: ...atures that make sys tem setup easy The Ethernet Bridge in this unit requires no configura tion at all The NetLink T1 provides T1 terminations over a modular RJ 48C jack and comply with jitter toleran...

Page 5: ...al Cisco router with a serial interface configured as a PPP Half Bridge The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote Ethernet network...

Page 6: ...s On 64 kbps 3 1 1 Switch S2 The table below shows the default configurations for Switch S2 A description of all S2 options follows this table Switches S2 1 S2 2 and S2 3 Use Switches S2 1 S2 2 and S2...

Page 7: ...ck your clock mode settings and Tx Clock Invert S1 3 settings Switch S2 8 Reserved 3 1 2 Switch S1 The chart below shows the default configurations for Switch S1 A description of all S1 options follow...

Page 8: ...operating parameters Follow the instructions below to configure the Model 2720 using the software selections 1 Plug the 9 pin male end of the cable to your terminal or com puter s DB 9 serial port and...

Page 9: ...each letter you type The maximum length of the password which can include any character the terminal can generate is 16 characters 6 The Model 2720 will then display the Main Menu screen 3 2 1 Introd...

Page 10: ...isfaction you can save the changes permanently by exe cuting the Save Changes command This will update the unit s configuration and save all the parameters to permanent mem ory Logoff For security log...

Page 11: ...ring of the network interface performance over the Facility Data Link FDL AT T TR 62411 says the Extended Superframe Format extends the DS1 superframe structure from 12 to 24 frames for a total of 463...

Page 12: ...PRMs The messages con tain the NI performance over the last four seconds Thus up to three consecutive messages may be lost without loss of information It is available only with ESF When ANSI T1 403 is...

Page 13: ...the line The duration of the loopback is limited by the loopback timeout setting See Unit Operations paragraph 3 2 4 on pages 32 and 33 Default Config Source Switch default Option EEPROM Switch The Mo...

Page 14: ...al DTE The Model 2720 Initiating a RL can be in one of the following states Idle No user controlled loopbacks are active TxPr The Model 2720 is sending the preparatory phase pattern lasting for approx...

Page 15: ...the eight status messages Excessive zeros EXZ i e lack of pulses detected This condition may occur if the unit is not connected to the network in which case the EXZ is displayed continuously If EXZ co...

Page 16: ...hot of the link performance To clear all counters press the Backspace key If your keyboard does not have this key you can press a two key combi nation to affect the same result Hold down the Ctrl key...

Page 17: ...n minutes 00 30 thirty minutes default setting 00 45 forty five minutes 01 00 one hour 01 30 90 minutes 02 00 two hours 03 00 three hours NEVER forever the unit will remain in loopback without user in...

Page 18: ...Port 10Base T Hub RJ 45 Pin No RJ 45 Pin No 1 TD 1 RD 2 TD 2 RD 3 RD 3 TD 6 RD 6 TD 4 3 T1 FT1 INTERFACE CONNECTION The Network Line Interface Line is an eight position keyed modu lar jack configured...

Page 19: ...e s not octet aligned 7 pulses WAN receive frame s aborted 8 pulses Detected WAN receive frame s with CRC 9 pulses Detected LAN receive frame s too large 10 pulses Detected LAN receive frame s not oct...

Page 20: ...RL The Remote Digital Loopback RL test checks the performance of both the local and remote NetLink T1 as well as the communication link between them Any characters sent to the remote NetLink T1 in thi...

Page 21: ...h the LAL and RDL tests to evaluate the unit s and the communication links When a 511 2047 or QRSS test is invoked the NetLink T1 generates a pseudo random bit pattern of 511 bits 2047 bits or 2 20 bi...

Page 22: ...47 QRSS Standards AT T TR62411 TR54016 ANSI T1 403 Power Supply 120VAC 60 Hz to 5VDC 300mA wall mount transformer or UI 100 240VAC 50 60 Hz to 5 VDC 2A desktop trans former Dimensions 3 5 L x 2 1 W x...

Page 23: ...SSIGNMENT RJ 48C T1 DS0 Network Interface Female Modular Jack Pin Signal 1 RX Data TIP 1 2 RX Data RING1 4 TX Data TIP 5 TX Data RING TRS Jack RS 232 Control Port Pin Signal Direction Tip Tx Data From...

Reviews: