Switch S1-1 through S1-4 

(Model 1185):  Async/Sync Data Rate

On Model 1185 Switches S1-1, S1-2, S1-3 and S1-4 set two

parameters: synchronous or asynchronous data rate and the maximum
transmission distance between two Model 1185s. 

Data Max 

Distance

S1-1

S1-2

S1-3

S1-4 Rate (kbps) in miles (km)

On

Off

Off

On

0-19.2 3.0 

(4.8)

On

Off

Off

Off

0-38.4 1.5 

(2.4)

On

On

On

Off

2.4 1.5 

(2.4)

Off

On

On

On

9.6

3.0 (4.8)

On

Off

On

Off

14.4

1.5 (2.4)

On

Off

On

On

19.2

3.0 (4.8)

Off

Off

On

Off

28.8

1.5 (2.4)

Off

Off

On

On

38.4

3.0 (4.8)

On

On

Off

On

48.0

3.0 (4.8)

Off

On

Off

Off

56.0

1.5 (2.4)

Off

Off

Off

On

64.0

3.0 (4.8)

Off

On

On

Off

72.0

1.5 (2.4)

Off

Off

Off

Off

128.0

1.5 (4.8)

On

On

Off

Off

144.0

1.5 (2.4)

Off

On

Off

On

192.0

1.5 (2.4)

On

On

On

On

256.0

1.5 (2.4)

7

Switches S1-5 and S1-6:  Clock Source

Switches S1-5 and S1-6 are set in combination to determine Model

1184 and 1185 transmit clock source.

S1-5

S1-6

Setting

Description

On

Off

Internal

Transmit clock 
generated internally

On

On

Internal

Transmit clock 
generated internally

Off

On

External

Transmit clock derived 
from terminal interface

Off

Off

Received Recover

Transmit clock derived 
from the received line 
signal

NOTE: Because communication between two Model 1185s is 
always synchronous, you must set these switches whether your 
application is async or sync
.  For X.21 or Async applications, 
please configure one unit for internal clock mode and the other for 
receive recover clock mode.

Switch S1-7:  DTE Control of DL

The setting for Switch S1-7 determines whether DTE control of

remote digital loopback test is enabled or disabled.  If DTE control is
disabled, the DL test can only be initiated by the front panel switch.  If
DTE control is not available, set switch S1-7 to the Off position.

S1-7

Setting

Description

On

Enabled

Respond to DL requests from DTE

Off

Disabled

Ignore DL requests from the DTE

Switch S1-8:  DTE Control of LAL

The setting for switch S1-8 determines whether DTE control of

local analog loopback test is enabled or disabled.  If DTE control is
disabled, the LAL test can only be initiated by the front panel switch.  If
DTE control is not available, set switch S1-8 to the Off position.

S1-7

Setting

Description

On

Enabled

Respond to LAL requests from DTE

Off

Disabled

Ignore LAL requests from the DTE

8

}

}

Async 
Settings

Sync
Settings

Summary of Contents for Kilolight 1184

Page 1: ...UAL MODEL 1184 MODEL 1185 Kilolight Single Fiber Modems SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1185 C Doc 035011U C Revised 08 16 99 An ISO 9001 Certified...

Page 2: ...lly disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 118...

Page 3: ...ptic cable Point to point distances up to 3 miles Internal external or receive recovered clocking options Field Replaceable DTE DCE QuickConnect interface modules V 24 RS 232 V 35 RS 422 530 X 21 and...

Page 4: ...itch package that allows configuration to a wide range of applications These switches are located on the bottom side of the PC board Figure 1 shows the switch locations with respect to the other compo...

Page 5: ...d from terminal interface Off Off Received Recover Transmit clock derived from the received line signal NOTE Because communication between two Model 1185s is always synchronous you must set these swit...

Page 6: ...ngeable QuickConnect Modules Each QuickConnect Module has a 50 pin card edge connector on one side and a serial port interface on the other Figure 2 below shows how a QuickConnect Module plugs into th...

Page 7: ...between manufacturers If you have any questions about a specific application contact Patton Technical Support at 301 975 1007 support patton com or at http www patton com 11 4 2 4 Re configuring the...

Page 8: ...en indicates that the remote modem s carrier is being received DTR Glows green to indicate that the Data Terminal Ready signal from the terminal is active ER Glows red to indicate the likelihood of a...

Page 9: ...pment is operating properly and can be used for a test If a fault is indicated call a technician or replace the unit 3 Perform a BER bit error rate test on each unit using a separate BER tester If the...

Page 10: ...V 35 X 21 Ethernet Bridge and G 703 Power 115 230 VAC switch selectable 50 60 Hz 5 Watts 85V 256 VAC 50 60 Hz universal input option 48 VDC option 5 Watts Regulatory FCC part 15 Class A Compliance UL...

Page 11: ...est Control B APPENDIX C cont RS 232 RS 530 and V 35 Interface Pin Description DB 25 Female Connector Pin Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS Clea...

Page 12: ...ming A 7 BT Byte Timing A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R Receive Data B 12 I Indication B 13 S Signal Element Timing B 14 BT Byte Timing B 21 22 APPENDIX C cont G 703 Int...

Reviews: