5.3  DIAGNOSTICS

Model 1184 and 1185 are equipped with V.54 diagnostics that may

be used to to evaluate the condition of the local and remote units, as
well as the twisted pair link between them: local  loopback (LAL) and
remote digital loopback (DL).

5.3.1 Local Analog Loopback

The Local Analog Loopback (LAL) test checks the operation of the

local Model 1184 or 1185 and is performed separately on each unit.
Any data sent to the local Model 1184/1185 in this test mode will be
echoed (returned) back to the user device. (See Figure 7, below).  For
example, characters typed on the keyboard of a terminal will appear on
the terminal screen.  

To perform a Local Analog Loopback test, follow these steps.

1.  

Activate LAL either  by moving the front panel toggle switch 
DOWN to “Local”, or;  by raising the appropriate signal on 
the DTE interface. Once Local Analog Loopback is 
activated, the Model 1184/1185’s transmit output is connected 
to its own receiver.  The test LED should glow.

NOTE: Although the local Model 1184/1185 cannot communicate with the remote
Model 1185/1185 in this mode, the synchronized connection between the two
modems remains intact.

2.  

Verify that the data terminal equipment is operating properly 
and can be used for a test.  If a fault is indicated, call a 
technician or replace the unit.

3.  

Perform a BER (bit error rate) test on each unit using a 
separate BER tester.  If the BER test equipment indicates no 
faults but the data terminal indicates a fault, follow the 
manufacturer's checkout procedures for the data terminal.  
Also, check the interface cable between the terminal and the 
Model 1184/1185.

15

5.3.2  Remote Digital Loopback

The Remote Digital Loopback test checks the performance of both

the local and remote Model 1184/1185, 

and the communication link

between them.  Any characters sent to the remote unit in this test mode
will be returned back to the originating device (see Figure 7).  

To perform an DL test, follow these steps:

1.  

Activate DL.  This may be done in one of two ways:  First, by 
moving the front panel toggle switch DOWN to “Remote”.  Or, 
second, by raising the DL signal on the terminal interface (for 
pin numbers, see Appendix D).

2. 

Perform a BER (bit error rate) test on the system, using BER 
testers on both ends.

3. 

If the BER test equipment indicates a fault and the Local 
Analog Loopback test was successful for both Model 1184 or 
1185s, you may have a problem with the line between the 
units.  You should inspect the line for proper connections.

Figure 7.  Remote Digital Loop

16

Figure 7.  Local Analog Loopback

Local Model 1184/1185

Summary of Contents for Kilolight 1184

Page 1: ...UAL MODEL 1184 MODEL 1185 Kilolight Single Fiber Modems SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1185 C Doc 035011U C Revised 08 16 99 An ISO 9001 Certified...

Page 2: ...lly disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 118...

Page 3: ...ptic cable Point to point distances up to 3 miles Internal external or receive recovered clocking options Field Replaceable DTE DCE QuickConnect interface modules V 24 RS 232 V 35 RS 422 530 X 21 and...

Page 4: ...itch package that allows configuration to a wide range of applications These switches are located on the bottom side of the PC board Figure 1 shows the switch locations with respect to the other compo...

Page 5: ...d from terminal interface Off Off Received Recover Transmit clock derived from the received line signal NOTE Because communication between two Model 1185s is always synchronous you must set these swit...

Page 6: ...ngeable QuickConnect Modules Each QuickConnect Module has a 50 pin card edge connector on one side and a serial port interface on the other Figure 2 below shows how a QuickConnect Module plugs into th...

Page 7: ...between manufacturers If you have any questions about a specific application contact Patton Technical Support at 301 975 1007 support patton com or at http www patton com 11 4 2 4 Re configuring the...

Page 8: ...en indicates that the remote modem s carrier is being received DTR Glows green to indicate that the Data Terminal Ready signal from the terminal is active ER Glows red to indicate the likelihood of a...

Page 9: ...pment is operating properly and can be used for a test If a fault is indicated call a technician or replace the unit 3 Perform a BER bit error rate test on each unit using a separate BER tester If the...

Page 10: ...V 35 X 21 Ethernet Bridge and G 703 Power 115 230 VAC switch selectable 50 60 Hz 5 Watts 85V 256 VAC 50 60 Hz universal input option 48 VDC option 5 Watts Regulatory FCC part 15 Class A Compliance UL...

Page 11: ...est Control B APPENDIX C cont RS 232 RS 530 and V 35 Interface Pin Description DB 25 Female Connector Pin Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS Clea...

Page 12: ...ming A 7 BT Byte Timing A 8 SGND Signal Ground 9 T Transmit Data B 10 C Control B 11 R Receive Data B 12 I Indication B 13 S Signal Element Timing B 14 BT Byte Timing B 21 22 APPENDIX C cont G 703 Int...

Reviews: