unit. This will cause the unit to enter a special mode. Then turn off the
unit and change the switch settings to the desired settings. When you
turn the unit on again, the unit will be set up with the selected switch
settings.

DS0 Channel Configuration Menu:  [ Bandwidth/# Channels = 
1,536/24 ]

(default)

The DS0 Channel Configuration Menu has a sub-menu that looks 
like this:

You may configure the Model 2710A to operate with any combina-

tion of active and inactive DS0 channels in this screen. When you exe-
cute the Save Changes command, the selected settings will be saved
to permanent memory, and the system will be updated to operate with
the new channel settings. 

NOTE:  In Unframed format, the Bandwidth Selected will display
“1,544k,” and the Total Channels will display “n/a.” When the DS0
Channel Rate is 56kbps, the Bandwidth Selected will be a multiple
of 56k, not of 64k. When using the DIP switches to set the band-
width, the starting channel is always channel 1.

3.2.3  System Diagnostics

The System Diagnostics/Statistics screen looks like this:

NOTE:  This screen is updated once per second.

The System Diagnostics/Statistics options and functions are

described below.

Local Loop: Idle 

(default)

The Local Loop is a bi-lateral loopback in which the data from the

local DTE and the data from the remote unit are looped back to their
respective sources (See Section 5.3).  Activate this loop to test the
each of the DTE’s connection to the Model 2710A.   

The Local Loop test has four states:

Idle

No user-controlled loopbacks are active.

LL

The Model 2710A is in local loopback mode.

Off

The Model 2710A is in remote or CO initiated loopback
mode or sending a pattern.  Local loopback is disabled.

LocP

The Model 2710A is in Local Loopback mode, and is
sending a test pattern.

a

n

Status of Rcvd
Test Pattern

2710A

2710A

Summary of Contents for 2710A Series

Page 1: ...MODEL 2710A Series T1 Fractional T1 to V 35 Converter T1 Fractional T1 CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M 2710A UM Doc 08614U2 001 Rev B Revi...

Page 2: ...Support at 301 975 1007 1 1 WARRANTY STATEMENT Patton Electronics warrants all Model 2710A Series components to be free from defects and will at our option repair or replace the product should it fail...

Page 3: ...pecifications found in Part 68 of the FCC rules and regulations A label on the equipment bears the FCC registration number You may be requested to provide this information to your telephone company Th...

Page 4: ...over Clocking Also Operates as a High Speed Point to Point Modem Compact Size Plugs Directly into a Router Switch or other DTE Made in USA 2 2 GENERAL PRODUCT DESCRIPTION The Model 2710A Series are si...

Page 5: ...Network interface parameters Configuration may be accomplished using pc board mounted DIP Switches or via software using the RS 232 control port 3 1 DIP SWITCH CONFIGURATION The Model 2710A has sixte...

Page 6: ...e Coding Off SW2 3 Line Framing Off SW2 2 DS0 Rate Clock On SW2 1 Clock Mode Off Contiguous Starting From Channel 1 ESF ANSI T1 403 64 kbps Network B8ZS 0dB Function SW2 2 SW2 1 Clock Mode Don t Care...

Page 7: ...dentical to AMI except that under certain circum stances the alternate polarity rule is deliberately violated AMI This stands for Alternate Mark Inversion The CSU DSU transmits data as a sequence of o...

Page 8: ...ts are now used for framing CRC and the Facility Data Link FDL The FDL allows maintenance messages and information to be passed between the 2710A and the Central Office Switch SW2 2 DS0 Channel Rate T...

Page 9: ...results Your terminal program s setup screen may differ from this one 4 When the unit is first turned on the terminal screen may appear blank Press the Enter key If your serial connection is good then...

Page 10: ...s options allow you to monitor the network performance initiate V 54 loops local loops and send test patterns Network performance parameters are updated once a second giving you the ability to quickly...

Page 11: ...F UNFRAMED This is a special mode that allows you to achieve the maximum possible data rate of 1 544 Mb s million bits per second by using the framing bits for data transmission There is no signaling...

Page 12: ...er DS0 channel to 56 kb s Your carrier will advise you on whether to use 64 or 56 kb s This is not available when using the Unframed format Clocking Network default Options Network Internal External N...

Page 13: ...to regain control should one be locked out after a loop back is initiated Remote In band Loops Enabled default Options Enabled Disabled In ESF D4 and Unframed formats the unit can respond to special r...

Page 14: ...56kbps the Bandwidth Selected will be a multiple of 56k not of 64k When using the DIP switches to set the band width the starting channel is always channel 1 3 2 3 System Diagnostics The System Diagno...

Page 15: ...he local unit then sends an all ones pattern before returning to the Idle state TxP The Model 2710A is sending a test pattern while in Test Mode IdlP The Model 2710A is sending a test pattern in place...

Page 16: ...s that the remote unit or the central office is sending a Blue Alarm because it is not receiving a sig nal the alarm is an unframed all ones signal mainly used to keep the line alive and to indicate t...

Page 17: ...looks like this factory default Header Line 1 Header Line 2 Headers 1 and 2 are provided for easy identification of your unit after installation You may want to give each unit a unique name via the h...

Page 18: ...interfaces This section briefly describes connection to each 4 1 DTE INTERFACE CONNECTION The DTE interface is a V 35 DCE presented as an M 34 male con nector This interface is designed to plug direct...

Page 19: ...niversal input 100 240VAC power supply The universal input power supply is equipped with a male IEC 320 power entry con nector Either power supply connects to the Model 2710A by means of a barrel jack...

Page 20: ...on Sending V 54 Loopback Pattern LED stays on PWR Power glows green to indicate that the unit is receiving power 5 2 LOOP V 54 TELCO DIAGNOSTICS The Model 2710A offers three V 54 loop diagnostics and...

Page 21: ...to clear all central office loops 5 3 BIT ERROR RATE V 52 DIAGNOSTICS The Model 2710A offers three V 52 Bit Error Rate BER test pat terns These test patterns may be invoked along with the LAL and RDL...

Page 22: ...ATTON ELECTRONICS MODEL 2710A CABLE RECOMMENDATIONS The Patton Electronics 2710A Series has been performance tested by Patton Electronics technicians using twisted pair cable with the fol lowing chara...

Page 23: ...GNMENT RJ 48C T1 DS0 Network Interface Female Modular Jack Pin Signal 1 RX Data TIP 1 2 RX Data RING1 4 TX Data TIP 5 TX Data RING TRS Jack RS 232 Control Port Pin Signal Source Tx Data From Model 271...

Page 24: ...Clock DTE Source KK Aux Power Input 5VDC 300mA APPENDIX E PATTON ELECTRONICS MODEL 2710A POWER SUPPLY INTERFACE Via Main 5VDC power jack J1 Center Pin 5VDC 300 mA Outer Barrel Ground Jumper Position f...

Reviews: