Loop Timeout
The Loop Timeout setting can be set to one of the following:
00:05 =
five minutes
00:10 =
ten minutes
00:15 =
fifteen minutes
00:30 =
thirty minutes (default setting)
00:45 =
forty-five minutes
01:00 =
one hour
01:30 =
90 minutes
02:00 =
two hours
03:00 =
three hours
NEVER =
forever—the unit will remain in loopback without user
intervention.
Set to Default Configuration
You may set the Model 2710A to its factory default configuration,
except for the header lines and the password, by executing the Set to
Default Configuration command.
Service Information
If you need to contact us for help, you can view the Service
Information screen. Here is what it looks like:
4.0 INSTALLATION
The Model 2710A is equipped with DTE, network, and power
interfaces. This section briefly describes connection to each.
4.1 DTE INTERFACE CONNECTION
The DTE interface is a V.35 DCE presented as an M/34 male con-
nector. This interface is designed to plug directly into a DTE interface
(See Appendix D for V.35 interface pin assignments).
4.2 NETWORK INTERFACE CONNECTION
The Network Line Interface is an eight position keyed modular jack
configured as a RJ-48C. This interface will need to be configured to
match the line parameters (i.e. framing, line coding, etc.) supplied by
the central office.
Figure 3. Model 2710A twisted pair line interface.
1 RX Data (TIP)
2 RX Data (RING)
3 (no connection)
4 TX Data (TIP)
5 TX Data (RING)
6 (no connection)
7 (no connection)
8 (no connection)
1
2
3
4
5
6
7
8
c
d
e
NOTE:
If the Model 2710A is being used for private short range
modem applications, the twisted pair cable connected to
its port will need to be a crossover cable. See Appendix
D for Interface pin assignments.