4.2  WIRING FOR MULTIPOINT CIRCUITS

The Model 2089 supports multi-point applications using either a

star or daisy chain topology.  Both topologies require special wiring, as
well as specific DIP switch settings for master and slave units.  Refer to

Section 5.0

for multipoint DIP switch settings

.

4.2.1  STAR TOPOLOGY

Using a star topology, you may connect several Model 2089s

together in a master/slave arrangement.  Maximum distance between
the units will vary based upon the number of drops, data rate, wire
gauge, etc.  Call Technical Support for specific distance estimates.

Figure 5 (below) shows how to wire the two-pair cables properly for

a Model 2089 star topology.  Note that the ground connection is not
needed.

4.2.2  DAISY CHAIN TOPOLOGY

Using a daisy chain topology, you may connect several Model

2089s together in a master/slave arrangement.  Maximum distance
between the units will vary based upon the number of drops, data rate,
wire gauge, etc.  Call Technical Support for specific distance estimates.

(Continued)

Figure 6 (below) shows how to wire the two-pair cables properly for

a Model 2089 daisy chain topology.  Note that the ground connection is
not needed.

4.3   CONNECTION TO THE EIA/TIA-574 INTERFACE 

The Model 2089 is designed to plug directly into the DB-9 serial

port of an EIA/TIA-574 DTE device (PC, laptop, host).  If you must use
a cable to connect the Model 2089 to the DTE device, make sure that it

15

HOST

FIRST SLAVE

OTHER SLAVE(S)

XMT+---------------------RCV+ -----------------------RCV+
XMT- ---------------------RCV- -----------------------RCV-
RCV+---------------------XMT+ -----------------------XMT+
RCV- ---------------------XMT- -----------------------XMT-

Figure 6.

Daisy chain wiring for Model 2089 host and slaves

Summary of Contents for 2089

Page 1: ...iniature DB 9 EIA TIA 574 to RS 485 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2089 E Doc 047043U Rev F Revised 1 22 08 C E R T I F I E D...

Page 2: ...used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2089 has been tested and found to comply with the lim...

Page 3: ......

Page 4: ...45 Silicon Avalanche Diode surge protection 2 2 DESCRIPTION The Model 2089 EIA TIA 574 to RS 485 interface converter provides exceptional versatility in an ultra miniature package Requiring no AC pow...

Page 5: ......

Page 6: ...nd S2 are marked with individual switch numbers 1 thru 4 Use these numbers as well as the ON designation to orient the switch properly see Figure 4 below Use a small screw driver or similar instrument...

Page 7: ......

Page 8: ...s the amount of delay between the time the Model 2089 sees RTS and when it sends CTS Note RTS CTS Delay setting should be based upon transmission timing S2 2 Setting On 8 mSec Off no delay S2 3 and S2...

Page 9: ......

Page 10: ...onditioned dry metallic wire between 19 and 26 AWG the higher number gauges may limit distance Standard dial up telephone circuits or leased circuits that run through signal equalization equipment are...

Page 11: ......

Page 12: ...irmly If your cable diameter is too small or too large for our strain relief please contact our technical support We have strain relief assemblies to accommodate most cable diameters 9 Insert the stra...

Page 13: ......

Page 14: ...RJ 11 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 1 6 GND RCV 2 4 XMT XMT 3 5 RCV XMT 4 2 RCV RCV 5 3 XMT GND 6 1 GND Connection to ground is optional RJ 45 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 2 7 GND...

Page 15: ......

Page 16: ...the ground connection is not needed 4 2 2 DAISY CHAIN TOPOLOGY Using a daisy chain topology you may connect several Model 2089s together in a master slave arrangement Maximum distance between the uni...

Page 17: ......

Page 18: ...S Surge Protection 600W power dissipation at 1 mS Power Draws operating power from EIA TIA 574 data and control signals no AC power or batteries required If necessary 6 12 VDC can be applied to pin 9...

Page 19: ......

Page 20: ......

Reviews: