3.1.3  DIP SWITCH S2 SETTINGS

DIP switch S2 is used to configure carrier control, RTS/CTS delay

and communication protocol.  The summary table below shows the
factory default settings for switch S2.  Following the summary table is a

detailed description of each individual switch.

*Note: 

Switches S2-3 and S2-4 should be switched simultaneously

S2-1:  Carrier Control Method

The setting for switch S2-1 determines whether the carrier is

“Constantly On” or “Controlled by RTS”.  This setting allows for
operation in switched carrier, multipoint and/or hardware handshaking
applications.

S2-1

Setting

On

Controlled by RTS

Off

Constantly On

S2-2:  RTS/CTS Delay

The setting for switch S2-2 determines the amount of delay

between the time the Model 2089 “sees” RTS and when it sends CTS.

Note

:  RTS/CTS Delay setting should be based upon transmission

timing.

S2-2

Setting

On

8 mSec

Off

no delay

S2-3 and S2-4:  “Transmit Off” Impedance

Switches S2-3 and S2-4 are set together to determine whether the

receiving device “sees” the impedance of the Model 2089’s transmitter
as being “high” or “intermediate” when the transmitter is turned off.  The 
“intermediate” setting is useful in half-duplex environments where the
receiving device does not respond well to the “high” setting.

S2-3

S2-4

Setting

On

On

Intermediate Impedance

Off

Off

High Impedance

7

SWITCH S2 SUMMARY TABLE (factory defaults in bold)

Position

Function

OFF Position

ON Position

S2-1

Carrier Control

Constantly ON

RTS

S2-2

RTS/CTS Delay

No Delay

8 mSec

S2-3*

“XMT Off” impedance 

High

Intermediate

S2-4*

“XMT Off” impedance

High

Intermediate

3.  Strip the insulation on each of the twisted pair wires about .25”.

4.  In a 

two pair circuit

, connect 

one pair

of wires to XMT+ and

XMT- (transmit positive and negative) on the terminal block, making
careful note of which color is positive and which color is negative.  

5. Connect the 

other pair

of wires to RCV+ and RCV- (receive

positive and negative) on the terminal block, again making careful note
of which color is positive and which color is negative.

Ultimately, you will want to construct a two pair crossover cable that

makes a connection with the two Model 2089s as shown below.

6.  In a 

single pair circuit

, use 

only the transmit (XMT) pair 

as

shown below:

Note:

If there is a shield around the telephone cable, it may be

connected to “G” on the terminal block.  To avoid ground loops, we
recommend connecting the shield at the computer end only.  A ground
wire is 

not necessary 

for proper operation of the Model 2089.

(Continued)

10

XMT+--------------------------------------------------RCV+
XMT----------------------------------------------------RCV-
G ----------------------

G

RCV+--------------------------------------------------XMT+
RCV----------------------------------------------------XMT-

To Shield (Optional)

}

One Pair

}

One Pair

XMT+--------------------------------------------------XMT+
XMT----------------------------------------------------XMT-

Summary of Contents for 2089

Page 1: ...iniature DB 9 EIA TIA 574 to RS 485 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2089 E Doc 047043U Rev F Revised 1 22 08 C E R T I F I E D...

Page 2: ...used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2089 has been tested and found to comply with the lim...

Page 3: ......

Page 4: ...45 Silicon Avalanche Diode surge protection 2 2 DESCRIPTION The Model 2089 EIA TIA 574 to RS 485 interface converter provides exceptional versatility in an ultra miniature package Requiring no AC pow...

Page 5: ......

Page 6: ...nd S2 are marked with individual switch numbers 1 thru 4 Use these numbers as well as the ON designation to orient the switch properly see Figure 4 below Use a small screw driver or similar instrument...

Page 7: ......

Page 8: ...s the amount of delay between the time the Model 2089 sees RTS and when it sends CTS Note RTS CTS Delay setting should be based upon transmission timing S2 2 Setting On 8 mSec Off no delay S2 3 and S2...

Page 9: ......

Page 10: ...onditioned dry metallic wire between 19 and 26 AWG the higher number gauges may limit distance Standard dial up telephone circuits or leased circuits that run through signal equalization equipment are...

Page 11: ......

Page 12: ...irmly If your cable diameter is too small or too large for our strain relief please contact our technical support We have strain relief assemblies to accommodate most cable diameters 9 Insert the stra...

Page 13: ......

Page 14: ...RJ 11 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 1 6 GND RCV 2 4 XMT XMT 3 5 RCV XMT 4 2 RCV RCV 5 3 XMT GND 6 1 GND Connection to ground is optional RJ 45 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 2 7 GND...

Page 15: ......

Page 16: ...the ground connection is not needed 4 2 2 DAISY CHAIN TOPOLOGY Using a daisy chain topology you may connect several Model 2089s together in a master slave arrangement Maximum distance between the uni...

Page 17: ......

Page 18: ...S Surge Protection 600W power dissipation at 1 mS Power Draws operating power from EIA TIA 574 data and control signals no AC power or batteries required If necessary 6 12 VDC can be applied to pin 9...

Page 19: ......

Page 20: ......

Reviews: