2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.

This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor.  If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

• Operates asynchronously, point to point or multipoint,

over 2 or 4 wires

• Up to 50 multipoint device drops in a polling environment

• Data rates to 115.2 Kbps

• Passes transmit & receive data, one control signal each direction

• No AC power or batteries are required

• Variable high/low impedance settings

• Able to operate with or without “echo”

• Carrier can be set as “constantly on” or “controlled by RTS” 

• Ultra-miniature size (2.50" x 1.20" x 0.75")

• Twisted pair connection via strain relief, RJ-11 or RJ-45

• Silicon Avalanche Diode surge protection

2.2  DESCRIPTION

The Model 2089 EIA/TIA-574 to RS-485 

interface converter

provides exceptional versatility in an ultra-miniature package.
Requiring no AC power or batteries for operation, the Model 2089
supports asynchronous communication up to 115.2 Kbps over one or
two unconditioned twisted pair.  Distances up to 15.0 miles are
attainable at lower data rates (1.2 Kbps, 19 AWG twisted pair).  

The Model 2089 can handle up to 50 terminal drops in a multipoint

polling environment.  For RS-485 applications requiring hardware
handshaking, the Model 2089 passes one control signal in each
direction.  The Model 2089 may be configured for high or low
impedance, carrier may be set to “constantly on” or “controlled by RTS”,
and the unit can operate with or without “echo”.  RTS/CTS delay may
be set for “no delay” or 8 mS.

Options for twisted pair connection include terminal blocks with

strain relief, RJ-11 or RJ-45.  Silicon Avalanche Diodes provide 600
watts per wire of protection against harmful data line transient surges.

3

14

HOST

FIRST SLAVE

SECOND SLAVE

XMT+

RCV+

RCV+

XMT-

RCV-

RCV-

RCV+

XMT+

XMT+

RCV-

XMT-

XMT-

Figure 5. 

Star wiring for Model 2089 host and slaves

Summary of Contents for 2089

Page 1: ...iniature DB 9 EIA TIA 574 to RS 485 Interface Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2089 E Doc 047043U Rev F Revised 1 22 08 C E R T I F I E D...

Page 2: ...used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 2089 has been tested and found to comply with the lim...

Page 3: ......

Page 4: ...45 Silicon Avalanche Diode surge protection 2 2 DESCRIPTION The Model 2089 EIA TIA 574 to RS 485 interface converter provides exceptional versatility in an ultra miniature package Requiring no AC pow...

Page 5: ......

Page 6: ...nd S2 are marked with individual switch numbers 1 thru 4 Use these numbers as well as the ON designation to orient the switch properly see Figure 4 below Use a small screw driver or similar instrument...

Page 7: ......

Page 8: ...s the amount of delay between the time the Model 2089 sees RTS and when it sends CTS Note RTS CTS Delay setting should be based upon transmission timing S2 2 Setting On 8 mSec Off no delay S2 3 and S2...

Page 9: ......

Page 10: ...onditioned dry metallic wire between 19 and 26 AWG the higher number gauges may limit distance Standard dial up telephone circuits or leased circuits that run through signal equalization equipment are...

Page 11: ......

Page 12: ...irmly If your cable diameter is too small or too large for our strain relief please contact our technical support We have strain relief assemblies to accommodate most cable diameters 9 Insert the stra...

Page 13: ......

Page 14: ...RJ 11 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 1 6 GND RCV 2 4 XMT XMT 3 5 RCV XMT 4 2 RCV RCV 5 3 XMT GND 6 1 GND Connection to ground is optional RJ 45 Cable 4 Wire SIGNAL PIN PIN SIGNAL GND 2 7 GND...

Page 15: ......

Page 16: ...the ground connection is not needed 4 2 2 DAISY CHAIN TOPOLOGY Using a daisy chain topology you may connect several Model 2089s together in a master slave arrangement Maximum distance between the uni...

Page 17: ......

Page 18: ...S Surge Protection 600W power dissipation at 1 mS Power Draws operating power from EIA TIA 574 data and control signals no AC power or batteries required If necessary 6 12 VDC can be applied to pin 9...

Page 19: ......

Page 20: ......

Reviews: