background image

5

3.0  CONFIGURATION

The Model 2042 is easy to install and is ruggedly designed for

excellent reliability.  The following instructions will help you set up and
install the Model 2042 properly.  

To use the Patton Model 2042, you must first configure the unit for

your application.  To do so, first open the case by inserting a flat head
screw driver into an open slot on either side of the case, as in Figure 1. 

Twist the screw driver head slightly and the top half of the case

will separate from the lower half, as in Figure 2. You now have access
to the internal switches used to configure the unit.

After opening the case, please refer to the section that pertains to

your unit for configuration details:

Patton Model Number

Section

Model 2042MC-MT....................................................3.1
Model 2042MT-MC....................................................3.2

To close the case, fit the 2 halves together snugly and snap them

back in place.

Figure 1:  Using a Small Screw Driver to Open the Model 2042 Case

Figure 2:  Using a Small Screw Driver to Open the Model 2042 Case

6

3.1  CONFIGURATION SWITCHES (MODEL 2042MC-MT)

The Model 2042MC-MT has miniature DIP switches that you may

use to configure the units.  Each Model 2042MC-MT is factory config-
ured as DCE on the RS-530 end, and DTE on the HSSI end.
Therefore, the RS-530 end “wants” to plug directly into a DTE device.
Conversely, the HSSI end of the converter “wants” to plug directly into
DCE.  

Please use this section to configure the internal DIP switches so

that the unit will work properly in your application.  Figure 3 shows the
position of the DIP switches on the top side of the PC board.

Figure 4 shows the orientation of the switches on DIP Switches S1

through S4 with respect to ON/OFF positions.  The default settings for
DIP Switch S1 are shown in the table 1 on page 6.  Detailed descrip-
tions of each switch follow the table. 

Figure 3. The Model 2042MC-MT Assembly Drawing

1234

Figure 4. Close-up of DIP Switches Showing “ON” and “OFF” Positions

1

2

3

4

ON

OFF

ON

DIP Switches S1 - S4

ON

OFF

Summary of Contents for 2042 Series

Page 1: ...e Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2042 UM Doc 07722U2 001 Rev D Revised 10 25 06 C E R T I F I E D An ISO 9001 Certified Company Copyrigh...

Page 2: ...es expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 2042 generates and uses radio frequ...

Page 3: ...ts synchronous data rates up to 10Mbps Transparent to synchronous protocol DB 25 and HD 50 connectors with integral 6 foot 1 8m cable Two versions available Model 2042MC MT Connects RS 530 DTE to HSSI...

Page 4: ...ew Driver to Open the Model 2042 Case Figure 2 Using a Small Screw Driver to Open the Model 2042 Case 6 3 1 CONFIGURATION SWITCHES MODEL 2042MC MT The Model 2042MC MT has miniature DIP switches that y...

Page 5: ...Off Not a Valid Setting Off On Data Skips Sync Circuit On Off Data passes through sync circuit On On Not a Valid Setting 2042MC MT DIP SWITCH SUMMARY TABLE Position Function Factory Default S1 Clock S...

Page 6: ...Function Factory Default S1 Gapped Clock On S2 Gapped Clock Off S3 Sync Method Off S4 Sync Method On No Gapped Clock Bypass Sync Circuit 10 4 0 INSTALLATION The Model 2042 is designed to connect RS 53...

Page 7: ...w shows the positions of the LEDs Following Figure 9 is a description of each LED Status Glows green to indicate that both DTR from the DTE device and DSR from the DCE device are active This LED will...

Page 8: ...imply converts and passes the data through the communication link The DCEs must be configured to perform to the appropriate loopback diagnostic 13 5 2 1 Local Loopback LL The Local Loopback LL test ch...

Page 9: ...IEC CE emissions Power Unit will require an external desk top power supply Temperature Range 0 to 50 C 32 122 F Humidity 5 to 95 non condensing Size 3 0 L x 1 8 W x 0 8 H 7 6 X 4 4 X 1 9 CM Approval...

Page 10: ...eserved for Future Use 39 43 Reserved for Future Use 19 Reserved for Future Use 44 Reserved for Future Use 20 23 Reserved for Future Use 45 48 Reserved for Future Use 24 TM Test Mode Indication A 49 T...

Page 11: ...19 20 APPENDIX D PATTON ELECTRONICS MODEL 2042MT MC BLOCK DIAGRAM APPENDIX E PATTON ELECTRONICS MODEL 2042MC MT BLOCK DIAGRAM...

Page 12: ...__________________________________________ ________________________________________________________ 21 NOTES ________________________________________________________ __________________________________...

Reviews: