4.3  AC POWER CONNECTION

The Model 2042 uses a 5VDC, 2A universal input, power supply

that is equipped with a male IEC-320 power entry connector and sup-
ports a voltage range of 100-240VAC.   This transformer connects to
the Model 2042 by means of a cannon jack on the rear panel.  There
are a variety of domestic and international power cords available for
the power entry (See Appendix B).  The Model 2042 is powered-up as
soon as it is plugged into an AC outlet–there is no power switch.  

4.4  DC POWER CONNECTION

The 36-60 VDC DC to DC adapter is supplied with the DC version

of the Model 2042.  The black and red leads plug into a DC source
(nominal 48VDC) and the barrel power connector plugs into the barrel
power supply jack on the 2042

.  

12

5.0 OPERATION

Once you have configured the Model 2042 properly (see Section

3.0) and have correctly connected DTE, DCE and power  (see Section
4.0), you are ready to operate the unit.  This section describes the LED
status monitors and loopback test modes.

5.1  BACK PANEL LED STATUS MONITORS

The Model 2042 features two LEDs that are located on the back

panel.  Figure 9 below shows the positions of the LEDs.  Following
Figure 9 is a description of each LED.

Status 

Glows green to indicate that both DTR (from the DTE 
device) and DSR (from the DCE device) are active.  
This LED will not be illuminated whenever one of the 
two signals are inactive.

Test Mode

Glows green to indicate that either one or both of the 
test modes are active (See Section 5.2 for a description
of the test modes).

5.2  TEST MODES

The Model 2042 supports two loopback modes that may be used

to evaluate  the condition of the communication links.  These modes,
(Local Loopback (LL) and Remote Loopback (RL), are always initiated
by the signals on the DTE 
device (See Figure 10).  This section
describes both loopback modes.

Figure 9. Model 2042 Rear Panel

External Power Jack

HSSI Cable

Test Mode LED

Status LED

NOTE:  

HSSI supports a third loopback mode: Local Digital

Loopback (LDL).  However, RS-530 does not support this mode.
In order to use LDL, the RS-530 device must be programmed to
respond according the the HSSI specification for LDL (See
TIA/EIA-613, Section 6.2.1 Local Digital Loopback (Loop A). 

To Power

Supply Jack

To -48VDC

Source

-Vin

+Vin

SWITCHING POWER SUPPL

Y

MODEL

 : SYD1

106-0505

INPUT

 : 36-60V      0.2A

 MAX

OUTPUT

 : +5V       1.0A

OUTPUT

 POWER : 5W MAX

S/N

: G01234567890

                             

MADE IN CHINA

 BY

 SUNNY

Black lead (-V)

Red lead (+V)

Barrel power connector

Summary of Contents for 2042 Series

Page 1: ...e Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2042 UM Doc 07722U2 001 Rev D Revised 10 25 06 C E R T I F I E D An ISO 9001 Certified Company Copyrigh...

Page 2: ...es expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 2042 generates and uses radio frequ...

Page 3: ...ts synchronous data rates up to 10Mbps Transparent to synchronous protocol DB 25 and HD 50 connectors with integral 6 foot 1 8m cable Two versions available Model 2042MC MT Connects RS 530 DTE to HSSI...

Page 4: ...ew Driver to Open the Model 2042 Case Figure 2 Using a Small Screw Driver to Open the Model 2042 Case 6 3 1 CONFIGURATION SWITCHES MODEL 2042MC MT The Model 2042MC MT has miniature DIP switches that y...

Page 5: ...Off Not a Valid Setting Off On Data Skips Sync Circuit On Off Data passes through sync circuit On On Not a Valid Setting 2042MC MT DIP SWITCH SUMMARY TABLE Position Function Factory Default S1 Clock S...

Page 6: ...Function Factory Default S1 Gapped Clock On S2 Gapped Clock Off S3 Sync Method Off S4 Sync Method On No Gapped Clock Bypass Sync Circuit 10 4 0 INSTALLATION The Model 2042 is designed to connect RS 53...

Page 7: ...w shows the positions of the LEDs Following Figure 9 is a description of each LED Status Glows green to indicate that both DTR from the DTE device and DSR from the DCE device are active This LED will...

Page 8: ...imply converts and passes the data through the communication link The DCEs must be configured to perform to the appropriate loopback diagnostic 13 5 2 1 Local Loopback LL The Local Loopback LL test ch...

Page 9: ...IEC CE emissions Power Unit will require an external desk top power supply Temperature Range 0 to 50 C 32 122 F Humidity 5 to 95 non condensing Size 3 0 L x 1 8 W x 0 8 H 7 6 X 4 4 X 1 9 CM Approval...

Page 10: ...eserved for Future Use 39 43 Reserved for Future Use 19 Reserved for Future Use 44 Reserved for Future Use 20 23 Reserved for Future Use 45 48 Reserved for Future Use 24 TM Test Mode Indication A 49 T...

Page 11: ...19 20 APPENDIX D PATTON ELECTRONICS MODEL 2042MT MC BLOCK DIAGRAM APPENDIX E PATTON ELECTRONICS MODEL 2042MC MT BLOCK DIAGRAM...

Page 12: ...__________________________________________ ________________________________________________________ 21 NOTES ________________________________________________________ __________________________________...

Reviews: