background image

3.2  CONFIGURATION SWITCHES SW1 - SW8

This section provides detailed information about the function of

each DIP switch and lists all possible settings.

Switch 1:  Hardware/Software Control/BERT Direction

The setting for Switch 1 determines whether the 2026P uses hard-

ware or software (i.e. XON/XOFF) flow control.  Switch 1 is alternative-
ly used to determine the direction of the BERT output message when-
ever the BERT is activated (See Switch 2, below).

Switch 2:  Bit Error Rate Test (BERT)

Use Switch 2 to activate a Bit Error Rate Test (BERT) in the direc-

tion of the serial 

or parallel interface.  This test can be used to deter-

mine whether the 2026P is working properly.  When BERT is activated,
the 2026P outputs the following Barber Pole pattern, which represents
every ASCII character on a standard US keyboard:

0123456789:;<=>?@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\}^_’abcdefghijklmnopqrstuvwxyz{|}~

NOTE: When you activate the BER Test, the 2026P “memorizes” the setting of
Switches S1, S3,S4, S5, S6, S7, and S8 to perform the test.  If you modify any of

these switches, you must de-activate Switch 2 in order for the changes to take effect.

5

Flow Control SW1
Hardware

OFF

Software

ON

BERT Direction SW1
Parallel

OFF

Serial

ON

Bit Error Rate

SW2

BERT Activated

ON

BERT De-activated

OFF

DIP SWITCH SUMMARY TABLE

Position

Function

Factory Default

SW1

Flow Control

Off

SW2

Bit Error Rate Test

Off

De-activated

SW3

Data, Parity, Stop Bits

Off

SW4

Data, Parity, Stop Bits

Off

SW5

Data, Parity, Stop Bits

Off

SW6

Data Rate

Off

SW7

Data Rate

Off

SW8

Data Rate

Off

Hardware

8B, NP, 1S

9600 bps

Switch 3 through 5:  Data, Parity and Stop Bit

Switches 3 through 5 are used to specify the data, parity and stop

bits.  The following table shows the settings that may be used:

Switches 6 through 8:  Frequency and Data Rate

Switches 6 through 8 determine the frequency and data rate. The

following chart shows the settings that may be used:

6

300

OFF

OFF

ON

600

ON

OFF

ON

1200

ON ON

OFF

2400

OFF

ON

ON

4800

ON

ON

ON

9600

OFF

OFF

OFF

19200

ON

OFF

OFF

38400

OFF

ON

OFF

Serial Data Rate

Data Rate

SW6

SW7

SW8

7B

EP

1S

ON

ON

ON

7B

OP

1S

OFF

ON

ON

7B

NP

2S

ON

OFF

ON

7B

EP

2S

OFF

OFF

ON

7B

OP

2S

ON

ON

OFF

8B

EP

1S

OFF

ON

OFF

8B

OP

1S

ON

OFF

OFF

8B

NP

1S

OFF

OFF

OFF

Stop

Data

Parity

Bit

SW3

SW4

SW5

Summary of Contents for 2026P

Page 1: ... 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2026P C Doc 102141UC Revised 6 8 98 MODEL 2026P Parallel to Serial Serial to Parallel Interface Converter C E R T I F I E D An ISO 9001 Certified Company ...

Page 2: ... rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If they do cause interference to radio or television reception which can be determined by disconnecting the RS 232 interface the user is encouraged to try to correct the interfer ence by one or mor...

Page 3: ... 25 female connector on the serial side and a Centronics 36 pin male connector on the parallel side Able to recieve power directly from the RS 232 interface the Model 2026P also comes with a wall mount power supply for low power applications 3 3 0 CONFIGURATION The Model 2026P is simple to install and designed for excellent reliability The following instructions will help you set up and install yo...

Page 4: ...f these switches you must de activate Switch 2 in order for the changes to take effect 5 Flow Control SW1 Hardware OFF Software ON BERT Direction SW1 Parallel OFF Serial ON Bit Error Rate SW2 BERT Activated ON BERT De activated OFF DIP SWITCH SUMMARY TABLE Position Function Factory Default SW1 Flow Control Off SW2 Bit Error Rate Test Off De activated SW3 Data Parity Stop Bits Off SW4 Data Parity S...

Page 5: ...here is no power switch 5 0 OPERATION Once your interface converter is properly configured and installed it should operate transparently as if it were a standard cable connec tion Operating power is derived from the RS 232 data and control sig nals there is no ON OFF switch 7 Figure 3 Installing the Model 2026P Model 2026P Serial Interface Parallel Interface PC Printer Your cable APPENDIX A PATTON...

Page 6: ...ransmit Data Power source when conn to DTE 3 RXD Receive Data sends XON XOFF only Power source when connected to DCE 4 RTS Request to Send Power source when connected to DTE 5 CTS Clear to Send Power source when conn to DCE 6 DSR Data Set Ready Power source when conn to DCE 7 SG Signal Ground 8 DCD Carrier Detect Power source when conn to DCE 9 V in Used as an external power source 20 DTR Data Ter...

Page 7: ...APPENDIX C PATTON MODEL 2026P BLOCK DIAGRAM Copyright 1998 Patton Electronics Company All Rights Reserved 11 ...

Reviews: