4.0  INSTALLATION

The Patton Model 2026P are very simple to install.  Once you

have configured the DIP switches, just plug your converter in to a stan-
dard cable and you’re ready to go.  Figure 3 illustrates the proper con-
nections for the Model 2026P.  If you have special-ordered a non-stan-
dard connector, your connections may be different.

4.1  POWER CONNECTION

In many cases, the Model 2026P will run without being connected

to external power.  However, additional power may be necessary in
certain applications that use low power RS-232 devices.  

The 120VAC U.S. wall transformer version su9V regulated

DC up to 500mA.  Connect this wall transformer to the Model 2026P
by means of a cannon jack on the side panel.  The Model 2026P is
powered-up as soon as it is plugged into an AC outlet–there is no
power switch.  

5.0  OPERATION

Once your interface converter is properly configured and installed,

it should operate transparently—as if it were a standard cable connec-
tion.  Operating power is derived from the RS-232 data and control sig-
nals; there is no “ON/OFF” switch.  

7

Figure 3.  Installing the Model 2026P

Model 2026P

Serial Interface

Parallel Interface

PC

Printer

Your cable

APPENDIX A

PATTON MODEL 2026P SPECIFICATIONS

Interface: 

Asynchronous, RS-232C compatible

Connectors:

Serial, DB-25 female; Parallel, 
Centronics 36 pin male 

Data Rates:

0 - 38,400 Kbps

Power Supply: 

1) Uses power from RS-232 interface;
2) 9VDC, 500mA power supply
3) Typical Maximum power consumption
= 100mW @5V (20mA)

Data Format: 

7 or 8 bits; 1 or 2 stop bits; even, odd or no 
parity

Flow Control:

[Serial Side as DCE = CTS (5)/DSR (6)]
[Serial Side as DTE = DTR (20)]

Temperature Range: 0-60

°

C (32-140

°

F)

Altitude:  

0-10,100 feet

Humidity:  

5 to 95% non-condensing

Dimensions: 

4.35” x 2.9” x 0.8” (11.0mm x 7.4mm x 
2.0mm)

Weight:  

2.6 oz. (73.8 grams)

8

Summary of Contents for 2026P

Page 1: ... 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2026P C Doc 102141UC Revised 6 8 98 MODEL 2026P Parallel to Serial Serial to Parallel Interface Converter C E R T I F I E D An ISO 9001 Certified Company ...

Page 2: ... rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If they do cause interference to radio or television reception which can be determined by disconnecting the RS 232 interface the user is encouraged to try to correct the interfer ence by one or mor...

Page 3: ... 25 female connector on the serial side and a Centronics 36 pin male connector on the parallel side Able to recieve power directly from the RS 232 interface the Model 2026P also comes with a wall mount power supply for low power applications 3 3 0 CONFIGURATION The Model 2026P is simple to install and designed for excellent reliability The following instructions will help you set up and install yo...

Page 4: ...f these switches you must de activate Switch 2 in order for the changes to take effect 5 Flow Control SW1 Hardware OFF Software ON BERT Direction SW1 Parallel OFF Serial ON Bit Error Rate SW2 BERT Activated ON BERT De activated OFF DIP SWITCH SUMMARY TABLE Position Function Factory Default SW1 Flow Control Off SW2 Bit Error Rate Test Off De activated SW3 Data Parity Stop Bits Off SW4 Data Parity S...

Page 5: ...here is no power switch 5 0 OPERATION Once your interface converter is properly configured and installed it should operate transparently as if it were a standard cable connec tion Operating power is derived from the RS 232 data and control sig nals there is no ON OFF switch 7 Figure 3 Installing the Model 2026P Model 2026P Serial Interface Parallel Interface PC Printer Your cable APPENDIX A PATTON...

Page 6: ...ransmit Data Power source when conn to DTE 3 RXD Receive Data sends XON XOFF only Power source when connected to DCE 4 RTS Request to Send Power source when connected to DTE 5 CTS Clear to Send Power source when conn to DCE 6 DSR Data Set Ready Power source when conn to DCE 7 SG Signal Ground 8 DCD Carrier Detect Power source when conn to DCE 9 V in Used as an external power source 20 DTR Data Ter...

Page 7: ...APPENDIX C PATTON MODEL 2026P BLOCK DIAGRAM Copyright 1998 Patton Electronics Company All Rights Reserved 11 ...