FUNCTION AND OPERATION(contiuned)
2. AUTO MODE (nighttime operation only)
Ɣ
To shift to “AUTO” mode, slide Time Delay switch to the desired time setting (between 5 seconds and 5 minutes). At dusk,
the light turns on to pre-selected low-level brightness. When motion is detected, the light turns to pre-selected high-level
brightness and stays on as long as motion continues. When the motion is no longer detected, the light at high-level
brightness remains on for the predetermined time you set (5S/1M/3M/5M), and then switches back to low level automatically.
Ɣ7KHOLJKWWXUQVRIIDXWRPDWLFDOO\DWGDZQ
Note: You can adjust the low-level (0~50%) and high-level (50~100%) brightness by using the brightness switch on the
back plate. (See Fig. 5)
3. CUSTOM SETTINGS MODE (nighttime operation only)
Ɣ$WGXVNWKHOLJKWZLOOWXUQVRQWRSUHVHOHFWHGKLJKOHYHOEULJKWQHVV$QGWKHOLJKWZLOOWXUQVRIIDXWRPDWLFDOO\DWGDZQ
Ɣ7RVZLWFKWRWKH³$872´PRGHDWWKHVSHFLILHGWLPHWXUQWKHZDOOVZLWFK³2))´WKHQWXUQLW³21´ZLWKLQVHFRQGVDW\RXU
specified time.And the light will switchs to “AUTO” mode automatically at the specified time every night. The light turns off
automatically at dawn. To revert to “CUSTOM SETTINGS” mode,turn the wall switch “OFF” then turn it “ON” within 5
seconds again.
Note: You can adjust the low-level (0~50%) and high-level (50~100%) brightness by using the brightness switch on the
back plate. (See Fig. 5)
Notes:
1. The sensitivity of the motion sensor will increase as the
environmental temperature gets cooler. You may wish to
make adjustments when the season changes.
For best performance, gently clean the lens with a soft
cloth every 1 or 2 months to assure maximum sensitivity.
2. For best performance, install fixture at least 8 feet above
the ground. At such a height, the fixture will provide a
detection distance of up to 70 feet at 77 degrees
Fahrenheit. (See Fig.6)
3. The sensor detects movement across a detection range
of 240 degrees. (See Fig.7)
4. The sensor will be more sensitive to motion across its
detection path than motion directly towards it. (See Fig.8)
5. To reduce possible nuisances, do not mount the fixture
near a heat source like an air conditioner, vent or furnace
exhaust, or in a direction facing any reflecting object or
other light source.
25'
8.0'
12.0'
70'
Where you install your fixture is important:
Be sure the light is mounted straight on the wall
or eave; otherwise, the detection distance may
be limited.
Fig. 6
Fig. 7
Motion
Least sensitive
Motion
Most sensitive
Sensor
Fig. 8
240'