- 27 -
PATON
ProMIG series
DC MMA/TIG/MIG/MAG
1) [But] torch button mode = [LFT] (by default)
a) [LFt]
–
contact striking mode TIG-LIFT
b) [2t]
–
non-contact striking mode, TIG-2T button mode
c) [4t]
–
non-contact striking mode, TIG-4T button mode
2) [Pr.A] preliminary current (pilot arc) = 15 А (by default)
a) 10... 40 A (increment 1 A) for PROMIG-200
b) 12... 40 A (increment 1 A) for PROMIG-250
3) [t.uP] current fade-in time = 1.0 s (by default)
a) 0.1... 5.0 s (increment 0.1 s)
4) [t.dn] current fade-out time = 2.0 s (by default)
a) 0.1... 5.0 s (increment 0.1 s)
5) [Po.A] crater filling
current = 20 А (by default)
a) 10... 60 A (increment 1 A) for PROMIG-200
b) 12... 60 A (increment 1 A) for PROMIG-250
6) [Po.P] current pulsing power = OFF (by default)
a) 0[OFF]... 80% (increment 1%)
7) [Fr.P] current pulsing frequency = 5.0 Hz (by default)
a) 0.2... 50.0 Hz (increment 0.1 Hz)
8) [dut] mark-to-space ratio (duty ratio) is the ratio of larger current cycle to pulse
spacing in percent = 50% (by default)
a) 20... 80% (increment 1%)
MIG/MAG welding mode
0) [-3-]
–
main displayed parameter VOLTAGE = 19.0 V (by default)
a) 12.0... 28.0 V (increment 0.1 V)
1) [t.dn] voltage fade-out time = 1.0 s (by default)
a) 0.1... 5.0 s (increment 0.1 s)
2) [Po.P] voltage pulsing power = OFF (by default)
a) 0[OFF]... 80% (increment 1%)
3) [Fr.P] voltage pulsing frequency = 20 Hz (by default)
a) 5... 200 Hz (increment 1 Hz)
4) [dut] mark-to-space ratio (duty ratio) is the ratio of larger voltage cycle to pulse
spacing in percent = 50% (by default)
a) 20... 80% (increment 1%)
8. ATTENDANCE AND TECHNICAL MAINTENANCE
Attention:
Before opening the machine, switch it off and disconnect the mains
plug. Wait until internal circuits of the machine de-energize (about 5 minutes), and