31 | P a g e
PATON
®
ADI 200 STANDARD TIG/MMA MIG/MAG
ATTENTION!
If button
(3)
is held for more than 12 s, the display will
show readouts 333 … 222 … 111 … 000. In this state, release the button
before the end of the readout indication period (000); otherwise, all the
values of the functions and parameters of the welding unit will return to the
default factory values set for the current welding process
(see Section 6.3)
6.3. SWITCHING TO THE REQUIRED WELDING PROCESS
After pressing the button
(4)
, the device switches to the next welding method. The methods switch
over and over, you can see it on the front panel
6.4. RESETTING ALL FUNCTIONS CURRENT WELDING METHOD
There might be conditions when the operator cannot set the welding unit parameters properly. In
this case, press button
(3)
and hold it for more than 12 s. At the 5th second, the welding unit will be
ready to switch to the next welding process. Nevertheless, hold the button. After 5 seconds, the
display will show readouts 333 … 222 … 111 … 000. When the readout is 000, the values of the
functions and parameters of the welding unit will return to the default factory set values. These
operations for setting default parameter values should be performed individually for all the welding
processes of the welding unit.
7.
GENERAL LIST OF FUNCTION SEQUENCES
7.1. MANUAL ARC WELDING PROCESS (MMA)
0) [-1-]
Basic indicated parameter:
Welding current 90 A (default value)
a)
8 … 160 A (adjustment 1 A) for ADI-160S
b)
10 … 200 A (adjustment 1 А) for ADI-200S
POWER HOT START
Current intensity in the increased-current arc starting mode:
40% (default value)
a)
0[OFF] ... 100 % at low currents (adjustment 1%)
TIME HOT START
Period of the increased-current arc starting
: = 0.3 s (default value)
a)
0,1 ... 1,0 s (adjustment 0.1 s)
POWER ARC FORCE
Voltage in the reduced-voltage welding mode:
= 40% (default
value)
a)
0 [OFF] … 100% at low currents (adjustment 1%)
TRESHHOLD
ARC FORCE
Threshold voltage for the reduced-voltage welding mode:
a)
9 … 18 V (adjustment 1 V)
VOLT-AMPER
CHARAKT.
Volt-ampere characteristic slope: =
1.4 V/A (default value)
a)
0.2 … 1.8 V/A (adjustment 0.4 V/A)
SHORT ARC MODE
Short arc welding mode:
= OFF (default value)
a)
ON
b)
OFF
VOLT REDUCTION
DEVICE
Reduction of voltage:
= OFF (default value)
a)
ON
b)
OFF
POWER PULSE
Current pulse amplitude:
=
OFF (default value)
a)
0 [OFF] … 80% (adjustment 1%)