– 9 –
7
Buzzer Settings
Caution
Do not use excess force when performing operations.
Failure to comply will result in damage due
to breakage or deformation.
Do not use sharp-pointed objects to perform operations.
Failure to comply may result in damage
and inoperative switches or hinder contact between contact parts.
Buzzer Unit
Bottom View
■
Indicates the position of the DIP
switch. (Down to turn “ON”.)
DIP Switch Con
fi
guration Table
Buzzer
Sound
DIP Switch
Sound Pattern
DIP Switch
Volume
1
2
3
No. 1
OFF
OFF
Rapid intermittent beep
(call sign)
OFF
Normal
No. 2
ON
OFF
Continuous beep sound
ON
Noise reduction
No. 3
OFF
ON
Rapid hi-low
Note: DIP Switch 4 is not used.
The factory default settings have all of the DIP
switches in the “OFF” (Up) position.
No. 4
ON
ON
Sweep sound