9
ASSEMBLY INSTRUCTIONS Model PH-45-FS-LP & Model PH-50-FS-N
Free standing model for use will approved flexible supply line.
S
tep 1
Determine a safe, level and suitable location for
the weighted base.
Step 2
Remove the 3/8” x 1” bolt in the base of the
heater head and set aside. (Figure 2 previous
page 7). Secure heater head to flexible hose
protruding from the top of the post. Use two
pipe wrenches to securely tighten. A suitably
approved gas pipe sealant must be used for all
gas connections. Slide head assembly into post.
Align the 3/8” hole in the post with the 3/8”
threaded hole in the base of the heater head, and
replace the 3/8” x 1” bolt. Secure tightly.
Step 3
Slide the decorative cover onto the post from the
bottom. Place the post into the basemount “T”
on the weighted base and slide the decorative
cover down over the post retainer. Connect gas
supply to nipple protruding from the lower end
of the tube. A suitably approved flexible gas
line must be used for connection to the gas
supply. Flex gas line is not included. Consult
the local authorities for information on the types
of flexible lines and quick connection couplers
that are available in your area.
Step 4
Secure the reflector to the heater head with the
hardware provided. Gas supply and electrical
supply are to be according to all local and
applicable codes. Only those individuals
licensed and qualified in the installation of gas
fired heating appliances are to install this
appliance.
Gas shutoff
by others
Dec orative
Cover
Weighted
base
Basemount “T”
top view