SET UP

X amplifiers run at about the same power as their output rating, and 
XA amplifier run more than twice that.  The heat sinks on the side 
of  the amplifier run hot to the touch – about 25 to 30 degrees C. 
above ambient, so you can expect 50 to 55 degrees C. temperatures 
on the heat sinks.  It is very important to the long life of  the 
amplifier that they get good ventilation.

You can put this amplifier anywhere you want, but it must have good 
ventilation.  Do not place it in enclosed cabinets or small closets 
without means for air to circulate freely.  Stacking these power 
amplifiers directly upon each other is not recommended for the same 
reason.  You should have a minimum of  about 6 inches clearance to 
the top and sides for adequate air circulation. 

When not actually intending to play music the amplifier should be 
left in standby mode, where it draws only a few watts of  bias on 
the output stage.  If  you wish to reduce the power draw to 0, you 
can shut the amplifier off  via the rear panel switch, however we 
recommend that for minimum noise this switch should be toggled in 
stand-by mode.

We have provided a standard IEC power cord that fits into the 
standard 15 amp IEC receptacle at the rear of  the amplifier chassis.  

With the exception of  the largest of  the X and XA series, there is no 
difficulty running two amplifiers on a single 15-amp circuit.  Given 
the high current draw, we generally do not recommend active line 
conditioners, although they are unlikely to damage the amplifier.

This amplifier is equipped for operation with an earth ground 
provided by the users AC outlet.  Never defeat this ground 
connection.  The signal ground of  this amplifier is connected to 
earth through a power thermistor, which provides a safety ground 
but provides isolation from system ground loops.

For maximum safety we suggest that the power cord should be the 
last cable installed on your power-amplifier.  You may, if  you wish, 
substitute a 15-amp aftermarket power cord for the one we have 
supplied.  Only use power cords, which meet all local safety standards 
and carry acceptance marks from the local regulatory authority.  The 
power cord should be attached to the amplifier prior to plugging 
into house power.  Place the rear mounted switch in the off  (down) 
position before plugging in this amplifier. 

Summary of Contents for XA60.5

Page 1: ...1 pass XA60 5 Owner s Manual May 17 2007 ...

Page 2: ...power amplifiers based on the SuperSymmetric topology U S Patent 5 376 899 which elicits high power and performance from simple circuits with minimal feedback The first X amplifier the X1000 was intended as the premier example of the power of this principle delivering 1000 watts rms into 8 ohms at low distortion By itself of course this is no miracle but you have to consider that products with com...

Page 3: ...ts are the result of trial and error and extensive listening Measurement of performance is important to us and we feel that well designed product sounds good and measures good Apparently it is possible to make an amplifier which measures well but which does not please the ears and so we let our ears be the final judge X 5 and XA 5 amplifiers utilize the same basic circuit topology and gain devices...

Page 4: ...carefully and critically to our amplifiers with a wide variety of associated equipment and we take our time with it Musical performance is most important and is the basis of our success over the years It s true that we also value the other things The design and manufacturing decisions have to balance subjective performance against reliability cost specs and ego in approximately that order That is ...

Page 5: ... minimum noise this switch should be toggled in stand by mode We have provided a standard IEC power cord that fits into the standard 15 amp IEC receptacle at the rear of the amplifier chassis With the exception of the largest of the X and XA series there is no difficulty running two amplifiers on a single 15 amp circuit Given the high current draw we generally do not recommend active line conditio...

Page 6: ... noise and slightly less distortion They are recommended unless your favorite source component has only RCA outputs Also on the rear panel are the output connections for the loudspeakers On stereo amplifiers there is one pair per channel and on mono amplifiers we provide two pairs wired in parallel to facilitate bi wiring a loudspeaker As you are probably familiar the red one is positive polarity ...

Page 7: ...power cord from the wall while you connect the speakers and inputs Check to make certain that the loudspeaker cables aren t shorted at the loudspeaker end connect speaker cables to the output binding posts on the amplifiers observing correct polarity The output binding posts will accept either bare wire or spades Regulatory agencies in many countries have banned binding posts that will accept a ba...

Page 8: ...mall comfort to the few but take it easy and give us a call if you have problems People are interested in how long it takes for these amplifiers to break in Depending on the resolution of the rest of your audio chain you may or may not notice any break in of the amplifier beyond the first few hours of operation You will very likely notice the difference in sonic character between cold and normal o...

Page 9: ...uple hundred feet Fortunately this amplifier is not sensitive to the capacitive inductive character of some of the specialty speaker cables so feel free to experiment We have found that about 90 per cent of bad sounding cables are really bad sounding connections and we recommend that attention be paid to cleanliness of electrical contact surfaces and proper connector fit Speaker cables should be f...

Page 10: ...built industrial design not a frail tube circuit run on the brink of catastrophic failure If it breaks we will simply get it fixed so sleep well Pass Laboratories PO Box 219 24449 Foresthill Rd Foresthill CA 95631 USA www passlabs com sales passlabs com service passlabas com tel 530 367 3690 fax 530 367 2193 pass Pass Pass Labs Pass Laboratories Supersymmetery Aleph and Zen and are all registered ...

Page 11: ... 1 60 W Maximum Output Voltage 35 volts Maximum Output Current 20 amps Input Impedance 30 kohm balanced 15 kohm unbalanced Damping factor 150 ref 8 ohms nominal Slew rate 50 V uS Output Noise 150 uV unweighted 20 20 kHz Random noise floor 1 uV Dynamic range 150 dB random noise floor to peak output Balanced CMRR Balanced CMRR Balanced CMRR 60 dB 1 KHz DC offset DC offset DC offset 50 mv Power Consu...

Page 12: ...e and customer rights for product purchased outside the United States may vary depending upon the distributor and local laws Please check with your local distributor for specific information Any modifications to Pass Laboratories products that have not received written factory approval nullify all claims and void the warranty Should a modified product be returned to the factory for repair the owne...

Page 13: ...wer Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance Never under any circumstance insert a cut or damaged power cord into a mains power socket insert a cut or damaged power cord into a mai...