background image

7

MAINTENANCE

Paslode

®

 tools are built for ease of maintenance.  A few 

simple details will assure trouble-free operation and long 
tool life. Anyone who uses or maintains the tool must read 
the safety and maintenance instructions.  Study the sche-
matic drawing before starting any repairs on the tool.

Air-operated tools must be inspected periodically, and worn 
or broken parts must be replaced to keep the tool operating 
safely and ef

fi

ciently.  Also the items on the maintenance 

chart must be checked often.

Cold Weather Care

When temperatures are below freezing, tools should be 
kept warm by any convenient, safe method.  If this is not 
possible, the following procedure should be used to warm 
up the tools.

Reduce the regulated air pressure to 30 psi.

Remove all fasteners from the tool.

Connect an air line and blank fire the tool. The reduced

air pressure will be enough to free-

fi

re the tool. Slow speed 

operation tends to warm up the moving parts. Slowing up 
the piston helps the bumper and the O-rings to become 
springy.

Once the tool is warmed up, readjust the regulator to

the proper working pressure and reload the tool.

Open the drain on the air compressor tank to drain any

moisture at least daily in extremely cold or humid weather.
A few ounces of anti-freeze in the tank will keep the air
free of frost.

Testing the Tool After Servicing

After replacing any part or parts, it is important to check 
the tool for proper operation.  This ensures that the tool 
was put together correctly, is safe to use, and will perform 
the job properly.

Ensure that all hardware is tight.

Ensure that the work contacting element is installed

correctly in relation to the trigger, and that both parts move
freely.

Ensure that the magazine is properly attached.

Ensure that the required safety information on the tool

is legible.

Use only Paslode approved fasteners in the tool, and

ensure that they are correct for the application.

Ensure that a male air 

fi

tting is securely connected to

the tool.

Test the tool by driving fasteners into a workpiece iden-

tical to the tool's application.

Check the tool for air leaks during testing and for the

proper sequence of operation.

Ensure that all fasteners are driven to the same depth

and that the crown of the fastener is 

fl

ush with the work-

piece.

  

Most minor problems can be resolved quickly and easily
using the maintenance table that follows. If problems per-
sist, contact your Paslode dealer for assistance.

Summary of Contents for SCS200

Page 1: ...customer s responsibility to have all operators and service personnel read and understand this manual OPERATING MANUAL AND SCHEMATIC 515551 1 6 18 2018 Illinois Tool Works Inc Part 515700 MODEL SCS200...

Page 2: ...which proves to be defective within the specific time period Any replacement part or accessory provided in accordance with this warranty will carry a warranty for the balance of the period of warrant...

Page 3: ...male plug The inside diameter should be 28 7mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING AIR PRESSURE 80 to 120 p s i 5 5 t...

Page 4: ...s equipped with a safety mechanism called a work contacting element to help prevent accidental ring Never tamper with disable or remove the work contacting element Do not use the tool unless the work...

Page 5: ...pth of Drive Adjustment Disconnect the air supply The depth of drive adjustment is done by turning the adjustment wheel located below the trigger Clearing a Jam An occasional problem you may encounter...

Page 6: ...continue to bounce the work contacing element against the workpiece position ing the tool above as carefully as possible When the desired number of fasteners have been driven release the tool trigger...

Page 7: ...ool Open the drain on the air compressor tank to drain any moisture at least daily in extremely cold or humid weather A few ounces of anti freeze in the tank will keep the air free of frost Testing th...

Page 8: ...revent accumulation of moisture and dirt Prevent clogging of filter with dirt Prevent air leakage and pro mote efficient operation Promote operator safety and efficient tool operation Prevent jamming...

Page 9: ...nimum Adjust the depth of drive adjustment extend length Reduce air pressure Open front guide latch release jammed fastener and close latch securely Check magazine for proper fasteners Magazine follow...

Page 10: ...O Ring 21 515715 1 Cylinder Ring 22 515713 1 O Ring 23 502980 2 Step Pin 24 515407 1 Housing w Thead Insert 25 503222 2 O Ring 26 503224 1 Rolled Pin 27 503223 1 Rolled Pin 28 515704 1 Paslode Logo La...

Page 11: ...MODEL SCS200 16 Gauge Standard 1 2 Crown Stapler Part 515700 11...

Page 12: ...P Safety Glasses 382 1 0 4 o N t r a P r a e l C ACCESSORIES An Illinois Tool Works Company 120 Travail Road Markham ON L3S 3J1 2017 Illinois Tool Works Inc 12...

Page 13: ...de 1 2 po de calibre 16 MANUEL D UTILISATION ET SCH MAS 2018 Illinois Tool Works Inc 515551 1 6 18 IMPORTANT NE PAS D TRUIRE Il est de la responsabilit du client de s assurer que tous les utilisateur...

Page 14: ...ute pi ce ou tout accessoire qui s av re d fectueux au cours de la p riode de temps indiqu e Tout remplacement d une pi ce ou d un accessoire fourni dans le cadre de cette garantie disposera d une gar...

Page 15: ...AGRAFES Calibre 16 RACCORDS PNEUMATIQUES DE L OUTIL Cet outil utilise un raccord m le N P T de po Le diam tre int rieur doit tre d au moins 0 28 po 7 mm Le raccord doit tre capable de lib rer la pres...

Page 16: ...LIS Toujours d brancher l outil de l alimentation en air lorsqu il n est pas utilis lorsque vous quittez la zone de travail ou lorsque vous d placez l outil un autre endroit L outil ne doit jamais tre...

Page 17: ...her l alimentation en air Pour r gler la profondeur d entra nement tourner la roue de r glage situ e sous la g chette D gager un bourrage l occasion il est possible qu une attache se coince Du fait de...

Page 18: ...pi ce travailler en pla ant l outil au dessus de celle ci aussi soigneusement que possible Lorsque le nombre souhait d attaches a t atteint rel cher la g chette de l outil pour viter toute jection ac...

Page 19: ...r afin d liminer toute l humidit au moins une fois par jour dans des conditions extr mement froides ou humides Quelques onces d antigel dans le r servoir permettront de garder l air exempt de givre Te...

Page 20: ...ur l outil sont bien serr es Emp cher des fuites d air et favoriser un fonctionnement efficace V rifier les vis tous les jours S assurer que l l ment de contact fonctionne correctement Favoriser la s...

Page 21: ...utilisation de temps en temps aucune attache n est ject e V rifier que le magasin contient des attaches appropri es Le pourvoyeur du magasin doit glisser librement Si n cessaire retirer les d bris pr...

Page 22: ...drique 67 515721 1 Assemblage de pousseur 27 503223 1 Goupille cylindrique 68 515757 1 But e 28 515704 1 Logo Paslode 69 515758 1 Ressort 29 515705 1 Logo Paslode 70 515732 1 Ressort 30 502981 1 Joint...

Page 23: ...MOD LE SCS200 Agrafeuse couronne standard de 1 2 po de calibre 16 No de pi ce 515700 11...

Page 24: ...ACCESSOIRES Lunettes de s curit Transparentes An Illinois Tool Works Company 120 Travail Road Markham ON L3S 3J1 2017 Illinois Tool Works Inc 12 No de pi ce 401382...

Reviews: