ANOMALY
CAUSE
REMEDIES
Sudden shutdown
after a few minutes
from start
Ignition phase not completed
Restore the ignition phase
electric blackout
restart
blocked chimney
Clean the smoke duct
poor fuel
Change the type of fuel
lack of pellet
Fill the pellet tank if empty and
check the motor-driven screw
conveyor and the pellet feed
channel
The pellets
accumulate in the
brazier, the glass of
the door gets dirty and
the flame is weak.
Insufficient combustion air.
Make sure that the air intake in the
room is present and free. Clean the
brazier and check that all the holes
are clean. Carry out a general
cleaning of the combustion
chamber, exchanger and the
smoke duct. Check the condition of
the door seals.
poor fuel
change ttype of fuel
Smoke extraction motor faulty
Check operation and replace
the motor if necessary.
the fumes motor
does not work
electric blackout
Check the system and the
protection fuse
motor is broken
Check operation and replace the
motor if necessary.
faulty electronic board
replace electronic board
control panel faulty
replace display
446
Summary of Contents for SOFIA
Page 1: ...Produzione stufe e termostufe a pellets e policombustibili User manual SOFIA Ermetic Stove ...
Page 21: ...Motherboard Connections 18 ...
Page 27: ...CONSOLE 24 5 DISPLAY 5 1 ...
Page 28: ...28 25 ...
Page 29: ...USER MENU 26 5 2 USER MENU ...
Page 30: ...USER MENU 09 Technical menu 10 Abilita combustibile 11 Tipo combustibile under key 1 2 27 ...
Page 31: ...USER MENU 28 ...
Page 32: ...USER MENU 29 ...
Page 33: ... and so on up to PROGRAM 4 USER MENU 30 ...
Page 34: ...USER MENU 31 ...
Page 50: ...47 ...