user manual
A
ttention
It is forbidden to use nets and other devices that can obstruct the end of the flue
(including caps for gas boilers) and to use "T" (figure 8) or "H" (figure 9) shaped
terminals or open caps (figure 10).
In the event that the mouth of the
existing flue is not perpendicular to the
smoke outlet of the hearth, their
connection must be made using the
appropriate inclined fitting
(figure 7).
figura 6
f
igura 8
figura 9
figura 10
The exhaust system must be unique for each generator, no discharges in the flue
shared with other devices are allowed (figure 6).
(
figura 7
If the smoke exhaust is inserted inside a pre-existing flue, this must be certified for solid
fuels, be kept in optimal conditions and appropriately insulated.
An external flue pipe can only be used if it meets the following requirements:
Only insulated (double-walled) stainless steel pipes fixed to the wall should be used for the
ductsat the end of the duct there must be an inspection to perform periodic checks and
maintenance.The duct must be equipped with a windproof chimney and respect the
distances from the ridgeof the building (figure 11).
11
Summary of Contents for Flora
Page 1: ...Produzione stufe e termostufe a pellets e policombustibili User Manual Flora Flora Slim Steel ...
Page 23: ...user manual 22 ...
Page 24: ... user manual 23 ...
Page 25: ... user manual 24 ...
Page 26: ... user manual 25 ...
Page 28: ... user manual 27 ...
Page 31: ...user manual 30 ...
Page 35: ...user manual 34 ...
Page 36: ... Black Out a timing user manual 35 ...
Page 37: ...user manual 36 ...
Page 38: ...user manual 37 ...