USER MANUAL
IGNITION FAILURE ALARM
If the ignition of combustion is not detected, the display will show "AL 5 NO IGNITION".
To deactivate the alarm state, press the SET button (4) for a long time (approx. 2
seconds). The alarm stops and the stove first returns to the "FINAL CLEANING" state
and then to "OFF".
Before starting a new ignition cycle, the causes must be checked:
•
Check that the tank is full
•
Check that the brazier is in the correct position
Then, remove the unburned fuel from the burner.
ATTENTION: An excessive quantity of fuel in the b
urne
r, a wet fuel or a dirty brazier
make the ignition phase difficult. In the presence of these critical conditions, a dense
white smoke can form, capable of causing an explosion in the combustion chamber,
such as to shatter the glass.
Warning: never stand in front of the stove during the ignition phase if the fuel releases
dense smoke.
S
tove is equipped with all the safety systems necessary to minimize the risk of
glass breaking.
Attenton: If the appliance does not turn on regularly, the main cause
may derive from insufficient maintenance or poor quality of the fuel
used.
Clean as explained in the dedicated chapter.
20
Summary of Contents for Flora
Page 1: ...Produzione stufe e termostufe a pellets e policombustibili User Manual Flora Flora Slim Steel ...
Page 23: ...user manual 22 ...
Page 24: ... user manual 23 ...
Page 25: ... user manual 24 ...
Page 26: ... user manual 25 ...
Page 28: ... user manual 27 ...
Page 31: ...user manual 30 ...
Page 35: ...user manual 34 ...
Page 36: ... Black Out a timing user manual 35 ...
Page 37: ...user manual 36 ...
Page 38: ...user manual 37 ...