USER MANUAL
If the room temperature reaches the set temperature, the stove goes to the minimum
power level and the word "MODULA" appears in the last line of the display. This
modulation state ends only if the room temperature returns to being lower than the set
temperature. In this case the stove returns to the power set by the user and the
message "MODULA" disappears on the display and the standard work indications
return.
S
TOP
To switch off the stove, hold down key “4” for a few moments.
Once the shutdown signal has been received, the message “FINAL CLEANING” will
appear on the display while the fume extraction fan continues to operate at maximum
speed for a minimum time of about 10 minutes to ensure complete cooling of the
stove. The hot air fan also continues to operate until the stove cools down and turns
off.
ATTENTION: Never disconnect the power supply at this stage.
External thermostat installation
The operation of the stove can be regulated by an external room thermostat
connected to the electronic board
The connection of unsuitable thermostats could irreparably damage the electronic
board. This operation must only be carried out by specialized personnel.