Model No. PI-9877
Specifications
5
Combining Two Units
Two or more Power Supplies can be connected
in series
.
Connect the negative terminal of one unit to the positive terminal of the other.
Excessive voltage levels can be achieved when combining units in this way; students
should do so only under the supervision of a qualified instructor.
Storage
For easy storage of multiple units, indentations in the Power Supply
accept the feet of an identical unit stacked on top of it.
Function 4: Stair
(see page 25)
Programmable maximum voltage
Programmable step voltage: 0.01–18.00 V
Programmable minimum voltage
Programmable step time: 0.1–999 s
Programmable stair direction (ascending or descending)
Alternating stair direction option
Programmable number of cycles: 1 to 999, or infinite
Monitor voltage or current
Function 5: SET MAX
(see page 20)
Programmable voltage limit: 0.01–18.00 V
Programmable maximum current: 0.010–1.050 A
Automatic shutdown timer: 0.01–99.99 hours
“Hidden” Global Maximum voltage: 0.01–18.00 V (remembered after power off)
Function 6: PROGRAM
Custom program entry
(see page 28)
3–99 programmable voltage points (remembered after power off)
Edit modes: append, insert, delete point, delete entire program
Function 7: PLAY
Custom program output
(see page 29)
Programmable scale factor: 1–100% of programmed voltage
Programmable step-time: 0.1–999 s
Step-style and vector-style options
Programmable play direction (forward or backward)
Alternating play direction option
Programmable number of cycles: 1 to 999, or infinite
Monitor voltage or current
Summary of Contents for PI-9877
Page 1: ... DC Power Supply PI 9877 Instruction Manual 012 09125A ...
Page 18: ... DC Power Supply 18 T u t o r i a l ...
Page 36: ......