background image

DuraVIS-3400

  

23 

OSD Control Menu 

 

 
Vertical

: This slider moves the OSD left/right across the screen. 

 

Horizontal

: This slider moves the OSD up/down across the screen. 

 

Blend

: This slider sets the amount of blending of OSD into the background. 

 

Time out

: This slider sets the time, in seconds, in which the inactive OSD will shut itself down. 

 

OSD Zoom

: Enables and disables zooming into the OSD. 

 
 
 
 
 

Summary of Contents for DURAVIS 3400

Page 1: ...User Manual MNL 0545 01 revB REF ECO 1119 Effective 27 APR 07 DURAVIS 3400...

Page 2: ...on that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Parvus Parvus...

Page 3: ...ptible devices is not the responsibility of Parvus Further Parvus is not responsible for unauthorized modifications of Parvus equipment including the substitution or attachment of cables and or other...

Page 4: ...nces present in the equipment an improper use or disposal of the refuse can cause damage to human health and to the environment With reference to RAEE it is compulsory to not dispose of the equipment...

Page 5: ...tion to alert you to potential damage to a program system or device or potential personal injury The Mode of the register R W Read and write register RO Read only register W Meaning of the register wh...

Page 6: ...nector Descriptions 10 DB9 Male Serial 10 High Density DB15 VGA 11 DB9 Female Power Int 11 Chapter 3 Interconnection Cable Description 12 Chapter 4 Touch Screen Driver 13 Installing the Driver 14 Cali...

Page 7: ...escriptions of Color Functions 22 Descriptions of PIP Control Functions 22 OSD Control Menu 23 Factory Reset 24 Chapter 7 Troubleshooting 25 Technical Sales Assistance 25 Returning For Service 25 LIMI...

Page 8: ...play optimized for panel mount installations in ships aircraft and ground vehicles Its 400 Nit SVGA 800x600 resolution color Liquid Crystal Display is built into a robust mechanical design with intern...

Page 9: ...ut Standard VGA Video Input 800x600 Viewing Angle 160 degree conical 70 70 H 60 50 V Power Input Input 9 36VDC 12 28V nominal Vibe Isolation Internal Silastic Boot for Shock Vibration Isolation Materi...

Page 10: ...s used as an RS 232 interface for touch screen control The VGA connector serves as the video input to the display and the female DB9 connector is used for power input Front View Rear View DB9 Male Ser...

Page 11: ...NC Input VGA Signal 14 VSYNC Input VGA Signal 15 VGA_SCL Input VGA Signal DB9 Female Power Int Pin Number Signal Name Input Output Comments 1 Vin Input Incoming Power Interface Tied to Pin 6 2 Down In...

Page 12: ...round signals of the DB9 pins 7 or 8 are connected to the common of the Molex connector pin 1 of the external intensity control Pins 3 and 2 of the DB9 connector are connected to pins 3 and 2 of the b...

Page 13: ...n Driver Parvus provides a Windows XP driver and calibration program for the DuraVIS 3400 This chapter describes how to install this driver and run the calibration program Touch screen drivers for DOS...

Page 14: ...art using the touch screen After completing the preceding steps a new program labeled TPI Touch Screen Control Panel should be in your program directory This program is used to calibrate and change se...

Page 15: ...e or exit the OSD menu Button 3 Left Decrease This button is used to scroll left in the OSD menu It also decreases the value once an attribute is selected Button 4 Select This button is used to select...

Page 16: ...n Screen Menu All the display functions except for backlight intensity can be controlled and adjusted using an On Screen Menu This chapter explains all functions and their factory settings valid for F...

Page 17: ...DuraVIS 3400 17...

Page 18: ...g symbol and factory auto reset symbol By selecting one of these symbols and pressing the Enter key the sub menus will be displayed Main menu This menu is used to control the functions associated with...

Page 19: ...Allows Hue adjustment in the UV domain The modification affects all color channels and all input types Saturation Allows Saturation adjustment in the UV domain The modification affects all color chan...

Page 20: ...nge the settings for optimum image quality Phase This function is a slider to adjust the sampling phase of the analog interface For optimum image quality input pixels should be sampled at the ideal sa...

Page 21: ...of image zooming in and out Zoom Horizontal Pan Allows moving the zoomed image left and right Zoom Vertical Pan Allows moving the zoomed image up and down Vertical This slider moves the image up and...

Page 22: ...o one of two predefined values Color Temperature User can set the color temperature to either self defined values or to predefined values of 6500K or 9300K Red Green Blue These three sliders are used...

Page 23: ...screen Horizontal This slider moves the OSD up down across the screen Blend This slider sets the amount of blending of OSD into the background Time out This slider sets the time in seconds in which t...

Page 24: ...MNL 0545B 01 Factory Reset By selecting Yes and pressing enter the user can reload the factory settings All settings previously set by the user will be lost...

Page 25: ...ease contact your local Sales Representative Returning For Service Before returning any Parvus product you must contact Parvus to obtain a Returned Material Authorization RMA number Note You must have...

Page 26: ...nt Parvus disclaims and excludes all implied warranties of merchantability and fitness for a particular purpose The aggregate liability of Parvus arising from or relating to regardless of the form of...

Reviews: