8
4. CONTROLLER MODE
PAS-EMHK12 can work as
Controller, connected with the external Wiegand reader.
(Factory default mode)
--- 8 1#
Connection Diagram
Attention
: Install a 1N4004 or equivalent diode is needed when use a common power supply, or
the reader might be damaged (1N4004 is included in the packing).
4.1 Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand output format of the external
Reader.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Wiegand
input bits
8 (26~37) #
(factory default is
26bits)
3. Exit
*
4.2 Programming
Basic Programming is the same as Standalone Mode.
There are some exceptions for your attention.
PAS-
EMHK12 Connected with External Card Reader:
•
If EM card reader or HID card reader: users can be added/deleted on either PAS
- EMHK12
or external reader.
•
If MIFARE reader: users can only be added/deleted on external reader.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2.
OR
2.
1 (Press Fingerprint A once on
F2) #
(ID auto allocated)
1 (User ID) # (Press Fingerprint A
on F2) # (Select specific ID)
3.
Exit:
*