![Partizan PAS-EMHK12 Service Manual Download Page 7](http://html1.mh-extra.com/html/partizan/pas-emhk12/pas-emhk12_service-manual_3819690007.webp)
6
3.4 Delete Users
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
Delete Common Card User
2. Delete Card -
By Card
OR
2. Delete Card -
By ID number
OR
2.Delete User -
By Card number
2 (Read Card) #
The cards can be deleted
continuously.
2 (User ID) #
2 (Input 8/10 digits Card number)
#
Delete Common PIN User
2.Delete PIN -
By PIN
OR
2.Delete PIN -
By ID number
2 (Input PIN) #
2 (User ID) #
Delete Panic User
2.Delete Panic Card User
OR
2.Delete Panic PIN User
2 (User ID) #
2 (User ID) #
Delete All Users
2. Delete All Users
2 (Master Code) #
3. Exit
*
3.5 Set Relay Configuration
The relay configuration sets the behavior
of the output relay on activation.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Pulse Mode
OR
2. Toggle Mode
3 (1-99) #
(factory default)
The relay time is 1
-99 seconds.
(1 is 50mS)
(Default is 5 seconds)
3 0 #
Sets the relay to
ON/OFF
Toggle
mode
3. Exit
*
3.6 Set Access Mode
For Multi cards/PINs access mode, the interval time of reading cards/inputting PINs cannot exceed
5 seconds, or else, the
PAS-
EMHK12 will exit to standby automatically.
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Card access
OR
2. Card+PIN access
OR
2. Card or PIN access
OR
2. Multi cards/PINs access
4 0 #
4 1 #
4 2 #
(Factory default)
4 3 (2~9) #
(Only after reading 2~9 cards or
PINs, the door can be opened)
3. Exit
*
3.7 Door Detecting
Door Open Too Long (DOTL) warning:
when
used with an optional magnetic contact or built
-in
magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the
inside buzzer will beep automatically to remind people to close the door and continue for 1 minute
before switching off automatically.
Door Forced Open warning: When used with an optional magnetic contact or built
-
in magnetic
contact of the lock, if the door is opened by force, or if the door is opened after 60 seconds of the
electro-
mechanical lock not closed properly, the inside buzzer and alarm output will both operate.
Enter Master code # or valid user card /PIN to silence.