3.4 Delete Users 

 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode

 

* (Master Code) #

 

Delete Common Card User

 

 

2. Delete Card - 

By Card

 

OR

 

2. Delete Card - 

By ID number

 

OR

 

2.Delete User - 

By Card number

 

2 (Read Card) #

 

The cards can be deleted 

continuously.

 

2 (User ID) #

 

2 (Input 8/10 digits Card number) 

#

 

Delete Common PIN User

 

 

2.Delete PIN - 

By PIN

 

OR

 

2.Delete PIN - 

By ID number

 

2 (Input PIN) #

 

 

2 (User ID) #

 

Delete Panic User

 

 

2.Delete Panic Card User

 

OR

 

2.Delete Panic PIN User

 

2 (User ID) #

 

 

2 (User ID) #

 

Delete All Users

 

 

2. Delete All Users

 

2 (Master Code) #

 

3. Exit

 

*

 

 

3.5 Set Relay Configuration 

The relay configuration sets the behavior

 

of the output relay on activation.

 

 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode

 

* (Master Code) #

 

2. Pulse Mode

 

 

OR

 

2. Toggle Mode

 

3 (1-99) # 

(factory default)

 

The relay time is 1

-99 seconds.

 

(1 is 50mS) 

(Default is 5 seconds)

 

3 0 #

 

Sets the relay to 

ON/OFF

 Toggle 

mode

 

3. Exit

 

*

 

 

3.6 Set Access Mode 

For Multi cards/PINs access mode, the interval time of reading cards/inputting PINs cannot exceed 

5 seconds, or else, the 

PAS-

EMHK12 will exit to standby automatically.

 

 

Programming Step

 

Keystroke Combination

 

1. Enter Program Mode

 

* (Master Code) #

 

2. Card access

 

OR

 

2. Card+PIN access

 

OR

 

2. Card or PIN access

 

OR

 

2. Multi cards/PINs access

 

4 0 #

 

 

4 1 #

 

 

4 2 # 

(Factory default)

 

 

4 3 (2~9) #

 

(Only after reading 2~9 cards or 

PINs, the door can be opened)

 

3. Exit

 

*

 

 

3.7 Door Detecting 

Door Open Too Long (DOTL) warning: 

when 

used with an optional magnetic contact or built

-in 

magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the 

inside buzzer will beep automatically to remind people to close the door and continue for 1 minute 

before switching off automatically.

 

 

Door Forced Open warning: When used with an optional magnetic contact or built

-

in magnetic 

contact of the lock, if the door is opened by force, or if the door is opened after 60 seconds of the 

electro-

mechanical lock not closed properly, the inside buzzer and alarm output will both operate. 

Enter Master code # or valid user card /PIN to silence.

 

 

 

 

Summary of Contents for PAS-EMHK12

Page 1: ...Keypad PAS EMHK12 Service manual WWW PARTIZAN GLOBAL 2019...

Page 2: ...ers 3 5 Set Relay Con guration 3 6 Set Access Mode 3 7 Door Detecting 3 8 Set Strike out Alarm 3 9 Set Audible and Visual Response 3 10 Master Cards Usage 3 11 Users Operation Reset to Factory Default...

Page 3: ...face 12 28V AC DC voltage etc User Capacity Common Users Panic Users 600 598 2 Operating Voltage Idle Current Active Current 12 28V AC DC 65mA 100mA Proximity Card Reader Radio Technology Read Range H...

Page 4: ...r Code 0 New Master Code Repeat New Master Code Master code is any 6 digits 3 Exit Program Mode 2 2 Set Working Mode Notes Has 3 working modes Standalone Mode Controller Mode Wiegand Reader Mode choos...

Page 5: ...Follow the instructions according to your access configuration Notes User ID number Assign a user ID to the access card PIN in order to track it The common user ID number can be any number from 1 598...

Page 6: ...f cards to be enrolled Add PIN User 2 Add PIN Using Auto ID Allows PAS EMHK12 to assign PIN to next available User ID number OR 1 PIN The PINs can be added continuously PIN 4 6 digits 2 Add PIN Select...

Page 7: ...lti cards PINs access mode the interval time of reading cards inputting PINs cannot exceed 5 seconds or else the PAS EMHK12 will exit to standby automatically Programming Step Keystroke Combination 1...

Page 8: ...Using Master Cards to add and delete card PIN users Add a User 1 Read Master Add Card 2 Read User Card Repeat Step 2 for additional user cards 3 Read Master Add Card Delete a User 1 Read Master Delet...

Page 9: ...p Keystroke Combination 1 Enter Program Mode Master Code 2 Wiegand input bits 8 26 37 factory default is 26bits 3 Exit 4 2 Programming Basic Programming is the same as Standalone Mode There are some e...

Page 10: ...Keystroke Combination 1 Enter Program Mode Master Code 2 PIN input bits 8 4 or 8 or 10 factory default is 4bits 3 Exit Remarks 4 means 4 bits 8 means 8 bits 10 means 10 digits virtual number 4 4 Add...

Page 11: ...rol Yellow wire Buzzer control If you need to connect Brown Yellow wires When the input voltage for LED is low the LED will turn into Green and when the input voltage for Buzzer is low it will sound 5...

Reviews: