INSTRUCTIONS REF :IN111
ISSUE NUMBER : 3
DATE 10.08.15
PAGE 4 of 12
www.parry.co.uk
Cables
Appliances exceeding 3kw which are connected to a single phase supply should be wired
using 6mm² twin-and-earth flat cable, code designation 6242Y.
To connect a 3 phase and neutral supply, 5 wire 1.5mm² cable should be used with the code
designation HO5RRF. All flexible cables must comply to BS6500.
Access to the supply terminals at appliances exceeding 3kw is gained by the removal of the
panel at the rear of the appliance by four self-tapping screws. Pass the mains cable through
the hole in the panel and connect to the terminal block: see diagram on the reverse of panel
for the method which applies to your supply. After connection, ensure the back panel is firmly
secured back into position and the nylon cable is fitted.
Details of the machine current requirements are given on the rating label on the rear, and it
must be ensured that the correct type and rating or circuit breaker is used as protection for
your appliance.
Do Not Plug In Or Switch On Yet
Read the operating instructions for your appliance to make yourself familiar with its use. Also,
make sure whoever is operating the appliance is fully conversant with its working and aware of
the dangers of incorrect operation, or cleaning, especially the risk of burns and scalds from the
cooking medium, hot water or cooking plates.
We advise that these appliances should not be left unattended when switched on.