background image

 

   

 

 

INSTRUCTIONS REF :IN111 
ISSUE NUMBER : 3 
DATE 10.08.15 
PAGE 3 of 12 

 

 

 

www.parry.co.uk 

 

ENSURE THAT ALL THE SHELVES ARE FIRMLY IN PLACE 

 

OPERATING 

 

1.

 

Switch on power supply, the red lamp will indicate the power is ON 

 
2.

 

Turn the temperature dial to the required heat  setting,  the green lamp will show indicated 
power to the element and will extinguish when the desired temperature is reached. 

 
This  procedure  will  be  repeated  automatically  as  the  thermostat  maintains  a  constant 
temperature. 
 
For  the  best  results  from  your  new  plate  warmer,  pre-heat  the  machine  by  turning  the 
thermostat  to  maximum  (80°C)  for  approximately  20minutes.  We  recommend  that  you  load 
each shelf  with a maximum of 20 or 40 plates, depending on the width of the machine, giving 
a  total  machine  load  of  80  or  160  plates.  Anything  above  our  advised  limits  may  reduce  the 
efficiency of this machine 
 

Fitting a Different Plug 

 
Should you need to replace the plug connect the wires as follows: 
 
Green/Yellow wire   

 

To EARTH terminal (

)  

 
Brown Wire   

 

 

To LIVE (L) terminal of  new plug 

 
Blue Wire 

 

 

 

To NEUTRAL (N) terminal of the new plug  

 
Always  fit  the  same  value  fuses  as  that  originally  supplied  with  your  appliance.  Only  use 
BS1362 approved fuses. As a guide only, appliances under 700w can have a 3 amp fuse (red) 
and all others should have a 13 amp fuse (brown). 
 
When  disposing  of  an  old  plug  (particularly  the  moulded  type  which  has  been  cut  from  the 
mains cord) always remove the fuse as the plug could be dangerous if ever inserted into a live 
socket.  
 
 
 
 
 

Summary of Contents for 1832

Page 1: ...STRUCTIONS REF IN111 ISSUE NUMBER 3 DATE 10 08 15 PAGE 1 of 12 www parry co uk INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS CABINETS PLATE WARMERS MODEL 1832 1863 1869 1868 1888 921...

Page 2: ...ply before carrying out any installation work INSTALLATION 1 Choose a suitable site for your machine taking into consideration its use and any heat that may be generated whilst in service 2 Remove all...

Page 3: ...load each shelf with a maximum of 20 or 40 plates depending on the width of the machine giving a total machine load of 80 or 160 plates Anything above our advised limits may reduce the efficiency of t...

Page 4: ...diagram on the reverse of panel for the method which applies to your supply After connection ensure the back panel is firmly secured back into position and the nylon cable is fitted Details of the ma...

Page 5: ...etime Parry recommends that the appliance is serviced every 12 months by a Parry authorised engineer Failure to service your product within the initial 12 month warranty period will cause the 24 month...

Page 6: ...INSTRUCTIONS REF IN111 ISSUE NUMBER 3 DATE 10 08 15 PAGE 6 of 12 www parry co uk For units 1888 use this wiring diagram...

Page 7: ...MM HACABL003 1 1 1 1 1 CABINET LOOM LIVE 1880MM HACABL005 2 CABINET LOOM LIVE 635MM HACABL006 1 Cabinet Loom Neutral 1525MM 100MM HACABN001 1 1 1 1 Cabinet Loom Neutral 710MM HACABN002 1 1 1 1 1 CABIN...

Page 8: ...NICKEL PLATED WAFL20003 3 2BA SINGLE COIL SPRING WASHER WASC20000 7 4 6 M12 X 36MM X 2M WASHER ZINC YELLOW WASH03818 4 Warranty Policy The manufacturer s warranty is only valid in the UK mainland Nort...

Page 9: ...s instructions before placing a warranty call Or contact our warranty department on 01757 213909 for technical assistance ensure you obtain the model number before calling Please ensure you have read...

Page 10: ...ends maximum of 2kg Faulty electrics e g customers plug socket plug wiring junction box fault wrong fuse Any damages caused by the customer Lamps glass door gaskets Perspex baskets knobs all perishabl...

Page 11: ...Instead it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment Disposal must be carried out in accordance with local environmental regulat...

Page 12: ...tact details will be on the unit There will probably be a charge for this service which will depend on the physical size and location of the unit You will be given a collection price for a curb side c...

Reviews: