15
Control panel functions
Manual feed
Manual feed:
Use the icon 11 to fill the feed system (primer) only at a first startup or when the unit was turned
off by lack of fuel. The
UU
letters will be displayed for 90 seconds. Make sure all doors are closed when the
manual feed procedure is in operation. Never start the unit with this mode.
Display A & B
Display A
shows both the level of the combustion fan level (Icon 1 & 2) and ash removal level (Icon 3 & 4). The
Combustion Air display will appear when icons 1 or 2 are pressed (1 to 10 setting). The Ash Extractions display will
appear when Icons 3 or 4 are pressed (10 to 20 setting).
Display B
shows heat levels (1 to 5) and the cleaning mode (C1 and C2) as well as the error codes.
A screen saver is activated after 1 minute. To deactivate this mode, press one of the green or orange
icons (1 to 9). The key pad will then be accessible to change settings.
Feed rate calibration
The
calibration of the fuel features are not accessible when the unit is in start-up mode (A1 and A2). To activate
this mode, press the icon 11 for 10 seconds approx, a new configuration will appear on display A (0 by default).
This calibration can decrease or increase the amount of fuel per hour, ranging from -3 to +3. Refer to page 20
and 21 for more information.
Important: Setting -3, -2 and -1 are not functional for heat level 1 and s1, +2, +3 are not
functional for heat level 5.
Red light C and D
When the light C is red, it shows that the feed system is in operation.
When the light D is red, it shows the ash removal system is in operation.
Convection fan
This fan is used to propel hot air into the room. There is no adjustment for the convection fan. The convection fan
is factory set and is controlled by the heat level selected (1-5).