4
The exhaust air must not be discharged into an operating smoke or exhaust
flue, or into a shaft used for ventilating rooms in which a fireplace is located.
The exhaust must not share the flue of any other appliance.
After the initial installation check that the unit has been installed level to
avoid grease collection at one end.
When the canopy is located above a gas appliance the minimum distance
from the top of the cooking surface shall be 75cm and comply with the
relevant NZ standards.
When the canopy is located above an electric cooking surface the minimum
distance from the top of the cooking surface shall be 65cm and comply with
the relevant NZ standards.
If installation instructions for the gas hob you are using specify a greater
distance please follow the hob manufacturers recommendation.
Regulations concerning the discharge of air must be adhered to. Please refer
to the relevant NZ standards.
These hoods can be re-circulated using carbon filters available from Parmco
Appliances.
WALL FIXING
Drill two holes into the wall using the dimensions set out in (Fig.1) above. Ensure
that the screws are fixed into material suitable to carry the load of this unit.
Fix the two stirrups (see Fig. 2) in position ensuring screws are tightly fixed.
Place the stirrups into the special slots in the rear of the canopy.
Loosely fix the stirrups to the canopy with the screws provided in holes A (Fig.2).
A packer may be required depending on the depth of cabinetry being used and
the depth of the fascia panel being applied to the Tilta unit.